Enhancement of UV Detection Sensitivity in SFC Using Reference Wavelength Compensation
September 1st 2009Regulatory requirements for the identification, quantification, and control of impurities in drug substances and their formulated products are increasingly being explicitly defined, particularly through the International Conference of Harmonization (ICH).
Evaluation of a Multi-Mode ODS Column for the Separation of Polar Metabolites
September 1st 2009The analysis of polar, ionic metabolites is important for drug discovery and biomarker research. Often times, it is necessary to separate these metabolites from each other and biological matrixes prior to MS detection (1).
IgG Aggregation Using Online Fluorescent Dye Detection in HP-SEC and AF4
September 1st 2009To guide the development of aggregate free protein formulations, there is an urgent need for formulations, there is an urgent need for complementary methods which allow a sensitive detection, characterization, and quantification of different types of protein aggregates.
High Speed, High Resolution of Flavanones in Citrus Juice
July 2nd 2009Flavanones are a type of flavonoids occurring widely in plants, either in the aglycone backbone form itself or as glycosides. Flavonones exist in unique forms depending on the type of fruit and can be used to indicate the type of fruit that is being analysed. The following application introduces examples of high-speed analysis of flavanones in citrus juice using the Shimadzu ultra fast LC system, prominence UFLC, and the photodiode array detector SPD-M20A, focusing on narirutin, naringin, neohesperidin and hesperitin.
Stevia Sweetener Analyses using an Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Column
July 2nd 2009The FDA has no objection to Rebaudioside A having a generally recognized as safe (GRAS) status as a sweetener for food and drink.1 Stevia sweeteners may contain other steviol glycosides as well, mainly Stevioside, Rebaudioside C and Dulcoside A. Because the FDA GRAS confirmation is only for the use of Rebaudioside A at 95% purity or above in food and beverages, stevia extracts must be highly purified and characterized prior to use.
High Throughput Extraction of Melamine using EVOLUTE CX Mixed-mode SPE Plates
July 2nd 2009The use of EVOLUTE CX mixed-mode columns provides high and consistent recoveries across a range of complex matrices, from biological fluids to milk products. The dual retention mechanism ensures that matrix components such as proteins, salts and phospholipids are removed, resulting in lower ion suppression and accurate analysis.
The Use of Subtle Differences in Selectivity to Improve Separation of Structurally Diverse Analytes
July 2nd 2009The separation of structurally diverse analytes is often complicated by chance coelutions with other analytes or with matrix related compounds. Often the column is blamed, but while such coelutions make analysis difficult they do not necessarily indicate a faulty column, poor chromatography or method design.
Reduced Solvent Usage and Increased Throughput for PAH Analysis Using UHPLC
July 2nd 2009Polynuclear aromatic hydrocarbons (PAHs) are carcinogenic condensed ring aromatic compounds widely found as trace pollutants in waters, wastes, air particulates, soil and foods. PAHs can be routinely monitored using HPLC with a combination of UV and fluorescence detection as prescribed in EPA methods 550.1, 610 and 8310.
High Speed Separation of More Than 16 Polycyclic Aromatic Hydrocarbons
July 2nd 2009Polyaromatic hydrocarbons (PAH) are particularly relevant in the analysis of environmental pollution because of their ubiquity, toxicity and persistence. Consequently, the PAHs have become the most intensively studied pollutants in environmental analysis.
Rapid Screening of Pesticides Using U-HPLC/MS
The screening of pesticides, mycotoxins, and veterinary drugs is of great importance in regulated environments such as food or feed analysis. Due to some of the limitations of traditional triple quadrupole approaches (for example, targeted analyte detection, limited number of compounds, and unidentified unknown compounds), there is currently a trend towards use of full-scan MS data for the analysis of residue samples. Current screening approaches mainly rely on the use of ToF instruments coupled to U-HPLC delivering mass accuracy (~5 ppm) at a maximum resolution of <15,000. This can produce inaccurate mass measurements due the presence of unresolved background matrix interferences. In this work we show a full-scan MS screening approach with the Thermo Scientific Exactive mass spectrometer, a novel single-stage Orbitrapâ„¢ MS capable of providing precise mass accuracies at resolutions of up to 100,000 without the need for internal mass calibration.