Application Notes: General
Analysis of PCBs in Food and Biological Samples Using GC-Triple Quadrupole MS–MS
December 2nd 2008This application details a fast, reliable and highly selective trace-level screening method for the quantification of polychlorinated biphenyls (PCBs) in environmental, food and biological samples, using gas chromatography and a triple stage quadrupole mass spectrometer. The analytical strategy is analogous to the well-established US Environmental Protection Agency (USEPA) Method 1668A.
maXis High Resolution LC–MS Makes the Most of Ultrafast LC Separations
December 2nd 2008An ultrafast gradient LC separation method was developed to separate a 5-component drug mixture in 30 seconds, with peak widths of 1 second. maXis mass accuracy at sub-ppm levels and true isotopic pattern of the spectra from the peaks lead to a confident elemental formula assignment for each drug compound with the SmartFormula algorithm.
Overcoming Compound Volatility with Sub-ambient ELSD
October 6th 2008The success of evaporative light scattering detection relies on evaporating the eluent without destroying the analyte particle. Where the analyte is non-volatile, evaporator temperatures of 50-100 °C can be used without compound degradation, thus giving maximum sensitivity. However, when compounds have high vapor pressures and the eluent has a high boiling point (e.g. water), detection of semi-volatile compounds is problematic, because the evaporation temperature needs to be set at 30 °C or above in order to evaporate the solvent.
Agilent J&W Ultra Inert GC Columns: A New Tool to Battle Challenging Active Analytes
September 1st 2008QC test probes serve a vital function in ensuring the reproducibility of modern GC columns. These probes ensure that the columns have been properly deactivated, contain the correct amount of stationary phase, and have the same relative retention as the last column purchased. The choice of individual compounds in these test mixes varies widely and can have profound consequences on the performance of a column in the users' applications.
Synthetic Fused Silica Capillary Tubing: A Discussion of Diffusion
September 1st 2008Synthetic fused silica capillary tubing is commonly used as the preferred substrate for chromatographic separation columns. In limited instances the absorption and diffusion of molecules into and through the fused silica deserves consideration.
Fast Gradient LC Using Your Existing Instrumentation
September 1st 2008Transforming "standard" gradient HPLC systems into extremely fast gradient systems is readily achievable with proper application of chromatographic principles, particularly temperature control, combined with utilization of advanced HPLC columns. Bottom line: You don't have to buy a new LC to achieve ultra high quality and speed!
Ascentis® Express RP-Amide Expands the Selectivity of Fused-Core ™ Particle Technology HPLC Columns
September 1st 2008The Fused-Core particle consists of a 1.7 micron solid core and a 0.5 micron porous shell yielding a 2.7 micron diameter. One of the benefits of the Fused-Core particle is the small diffusion path (0.5 microns) compared to conventional fully porous particles. The shorter diffusion path minimizes peak broadening. In fact, there have been many reports on the vast improvements in efficiency provided by Fused-Core particles versus conventional particles. These improvements provide sub-2 micron like performance at half of the backpressure allowing Ascentis Express columns to be used in conventional HPLC as well as UHPLC systems.
Investigation of Branched Polydienes with GPC/MALS
September 1st 2008Our work focuses on the synthesis of branched (functionalized) polydienes via a facile two-step synthesis. Despite the numerous strategies developed for the preparation of branched polymers in recent years, there is still a limited number of simple synthetic strategies based on common vinyl monomers.
Reversed-Phase HPLC Column at Extreme High Temperature (150°C or Higher)
September 1st 2008In general, polymer-based columns have a broad pH range (pH 2 to 13), and some have high temperature tolerance (up to 150°C or higher). Considerably large selectivity changes can be obtained by varying analysis temperature and mobile phase pH. Having control on these two parameters over wide ranges can be especially useful in method development.
SELS - Solvent Enhanced Light Scattering
September 1st 2008Viscotek has been a strong advocate of good chromatography as a prerequisite for GPC (Gel Permeation Chromatography) data accuracy. Our recent work in application development has been driven by extremely difficult samples from industrial, biopharmaceutical, and academic sources. These samples present challenges ranging from sample solubility, column adsorption, as well as detection issues. This report will attempt to highlight a new approach that could be very helpful in certain advanced GPC applications.
Multi-Mode Water Soluble Vitamin Separation Using ZirChrom®-SAX
September 1st 2008Traditionally the analysis of water-soluble vitamins by reversed-phase HPLC has been complicated by the lack of retention for these compounds on conventional silica C18 columns. Here we demonstrate efficient, multi-mode, baseline resolution of six water-soluble vitamins in 6 min using a ZirChrom®-SAX column.
Branching in High Molar Mass Synthetic Amyloses
September 1st 2008Amylose is an occasionally-branched biopolymer and, together with amylopectin, the hyper-branched component, a constituent of starch. Determination of branching in amylopectin on the basis of amyloses may be performed with the help of synthetic amyloses. Synthetic amyloses from enzymatic (phosphorolytic) reaction were checked for their linearity.
Increasing LC–MS–MS Sensitivity with Luna HILIC
July 2nd 2008The analysis of polar compounds in support of clinical and preclinical pharmacokinetic studies requires an analytical methodology capable of achieving ultra-low detection and quantification limits. The high sensitivity afforded by coupling HPLC with tandem mass spectrometry (MS–MS) has made it the technique of choice in this environment, but it is subject to the following limitations when reversed-phase liquid chromatography (RPLC) is used
"Polymer Status" of Synthetic Oil Under REACH Context
July 2nd 2008Under the registration, evaluation and authorization of chemicals (REACH) Regulations (EG) no. 1907/2006 the producer, manufacturer or importer of chemical substances/formulations have to register their products (more than 1 ton/year) at the chemical agency.
Characterization of PEGylated Lysozyme by Size Exclusion and Ion Exchange Chromatography
July 2nd 2008PEGylation, the process by which polyethylene glycol (PEG) chains are attached to protein and peptide drugs is a common practice in the development of biopharmaceuticals to prolong serum half-life and improve pharmacokinetics of a drug. There is increasing demand for chromatographic methods to separate the modified isoforms from the native protein. This application note describes the use of size exclusion and ion exchange chromatography for the characterization of PEGylated lysozyme.
Flexible Fused Silica Capillary: A Review of Internal Surface Chemistry
June 1st 2008Synthetic fused silica capillary tubing has proven to be a vital component in many separation science techniques. Recently, it has expanded to serve an array of scientific markets. In most cases, an understanding of the internal surface chemistry is of fundamental importance.
Rapid Analysis of Flavors and Fragrances Using High-Efficiency GC Columns
June 1st 2008There are many misconceptions about what it means to perform fast gas chromatography (GC) and what the term fast GC implies. Fast GC is often associated with the use of hydrogen as a carrier gas and, although this is certainly a good approach, it is not always necessary to shorten the analysis time. A second misconception is that changing column dimension results in time-consuming method development. Using high-efficiency GC columns can greatly reduce the analysis time and when coupled with the method translation software, the time spent on method development can be greatly minimized.
SELS — Solvent Enhanced Light Scattering
June 1st 2008Viscotek has been a strong advocate of good chromatography as a prerequisite for GPC (Gel Permeation Chromatography) data accuracy. Our recent work in application development has been driven by extremely difficult samples from industrial, biopharmaceutical, and academic sources. These samples present challenges ranging from sample solubility, column adsorption as well as detection issues. This report will attempt to highlight a new approach that could be very helpful in certain advanced GPC applications.
Using pH-LC to Control Selectivity of Acidic and Basic Compounds on Gemini-NX
June 1st 2008The use of mobile phase pH to control analyte ionization states (pH-LCâ„¢) in reversed phase HPLC separations is a highly effective way to change selectivity. The ionized species of an analyte is shown to have higher polarity (less hydrophobicity) than the neutral species, which results in a loss of expected retention for that analyte. This can be attributed to less interaction with the hydrophobic stationary phase and greater affinity with the aqueous portion of the mobile phase. Ionized species also participate in ionic interactions with exposed and activated silanols, which impact peak shape and reproducibility.