Use of Alternative Solvents for Liquid Chromatographic Analysis of Cationic Surfactants
September 1st 2010Cationic surfactants are used as disinfectants, corrosion inhibitors, phase-transfer catalysts, wetting agents, dispersants, and even mobile phase modifiers in liquid chromatography.
Fractionation of Extractable Petroleum Hydrocarbons from Soil Using ISOLUTE® EPH SPE Columns
September 1st 2010ISOLUTE EPH columns have been developed to fractionate pentane or hexane based soil extracts into aliphatic and aromatic hydrocarbon fractions (C8?C40 aliphatics, C10?C22 aromatics).
A New High-Resolution MAbPac SCX Column for Characterization of Monoclonal Antibody Heterogeneity
September 1st 2010The new MAbPacTM SCX-10 column is based on 10 µm nonporous, highly cross-linked styrene-type polymeric media with a proprietary uniform hydrophilic coating that is grafted with sulfonic acid functional groups.
Effects of Various Acids and Acid Concentration on a ChiroSil® Crown-Ether Chiral Stationary Phase
September 1st 2010The Chirosil RCA(+) and SCA(–) chiral stationary phases (CSPs) are specialized chiral phases very effective in separating various natural and unnatural amino acids as well as compounds containing primary amines.
An Accurate and Robust LC–MS Method for the Identification of Illicit Drug Salt Forms
September 1st 2010Illicit cocaine, amphetamine, methamphetamine, and ecstasy (MDMA) are often encountered in the form of salts and identification of the specific counter ion present may provide valuable information about the source of production and the manufacturing pathway.
Fast, Low Pressure Analysis of Food and Beverage Additives Using Agilent Poroshell 120
September 1st 2010Agilent Poroshell 120, a superficially porous particle column, offers resolution and speed similar to columns packed with 1.8-µm totally porous particles, without generating high back pressure.
Next-Generation Autosampler for LC–MS Equipped with Straight Injection TechnologyTM
September 1st 2010This article reports a new sample injection mechanism for an autosampler that directly transfers a sample to column without passing it through any flow-changing device, and hence minimizes a delay volume and reduces a carryover signal to the extreme level.
The Application Notebook: A More Critical Resource Than Ever
September 1st 2010To the members of LCGC's readership, the science behind the headlines is always apparent. Separation science in general, and chromatography in particular, find application in nearly every facet of everyday life, from pharmaceutical analysis to the biomedical field to environmental testing, and this Application Notebook is a tribute to just how thoroughly separation science permeates our daily lives.