Improved Reproducibility of MW Measurements of Polypeptoids Using an EcoSEC GPC System
February 1st 2010The EcoSEC GPC System and a set of TSK-GEL mixed-bed columns, both available from Tosoh Bioscience, were used successfully for obtaining high quality MWD data of a series of block poly-β-alkylalanoids with HFIP as the mobile phase in under 15 min.
Flexible Fused Silica Capillary: Impact of Aging on Strength
February 1st 2010One of the most important attributes of flexible fused silica capillary tubing is its outstanding strength. When made properly with a protective abrasion resistant coating and handled appropriately this material has proven to maintain its strength remarkably well.
U.S. EPA Method 524.3 for Analysis of Volatile Organic Compounds (VOCs) in Finished Drinking Water
February 1st 2010The U.S. EPA Office of Groundwater and Drinking Water released Method 524.3, "Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry, Version 1.0," in the Federal Register on August 3rd, 2009 (1, 2).
17 Min D2712 Analysis of Impurities in Propylene Using PLOT Columns
February 1st 2010Capillary PLOT columns can be a simpler alternative to packed column setups for propylene analysis. Here we demonstrate a single column setup that provides fast baseline resolution of propylene impurities.
Profiling of Essential Oil VOCs and SVOCs by GC–TMS
February 1st 2010Spice and fragrance essential oil raw materials frankincense (Boswellia carterii) from India and Somalia, sandalwood (Santalum album) from India and Indonesia, and corn mint (Mentha haplocalyx) from the United States were analyzed for on-site analytical profiling and confirmation of quality and purity of therapeutic grade essential oils from raw materials.
Fractionation of Extractable Petroleum Hydrocarbons from Soil Using ISOLUTE® EPH SPE Columns
February 1st 2010ISOLUTE EPH columns have been developed to fractionate pentane or hexane based soil extracts into aliphatic and aromatic hydrocarbon fractions (C8–C40 aliphatics, C10–C22 aromatics).
An Empirical Evaluation of HILIC and Monolithic Columns for SFC Applications
February 1st 2010Separation of polar compounds by conventional reverse phase chromatography can be challenging due to their poor retention. Other HPLC approaches include normal phase chromatography (NPC) and its variation, hydrophilic interaction chromatography (HILIC).
Increased Efficiency and Resolution with Kinetex„ Core-Shell Technology
February 1st 2010Over the past several years column manufacturers have been introducing columns packed with smaller particle sizes – sub-2 µm and 3 µm – to take advantage of the improvements that such small particle size columns offer.
Generating Make-Up Gas for GC with an In-house Nitrogen Generator
February 1st 2010Since the gas flow required for the separation step in gas chromatography is frequently lower that that required to optimize the detection, nitrogen is used as a make-up gas to increase the gas flow for detection.