Flexible synthetic fused silica capillary is routinely supplied to the market in long continuous lengths on low cost Styrofoam or plastic spools.
Joe Macomber, Polymicro Technologies
Synthetic fused silica capillary tubing is a material of key importance in a broad range of analytical applications and is provided to the market in a variety of formats. This note discusses items to consider when specifying product packaging.
Flexible synthetic fused silica capillary is routinely supplied to the market in long continuous lengths on low cost Styrofoam or plastic spools. This packaging is well established and widely accepted. There are a variety of other product offerings, most of which are considered custom in nature (1). Scientists increasingly rely on Polymicro to provide these custom capillary products which include precision cleaved or saw cut pieces, windowed capillary, laser machined micro-components, and a variety of similar value added products. During design of these custom products, it is important to consider how the product should be packaged. Packaging can impact product quality, cost, and the efficiency of use upon receipt. Although there are a variety of options, there are also constraints of use. This note discusses some key packaging considerations.
A variety of packaging formats can be employed.
Bags: Simple, low cost polymer tube bags and Ziploc style bags can be specified. Higher quality, cleaner Level 100 bags are available in both tube and Ziploc format; these are noted for their low level of particulates and residue.
Tubes: Containers of either plastic or glass, similar to a sample vial or test tube can be used.
Well plates: These are an option for some high volume, smaller micro-components; often there is only one part per well. 96- or 384-well plates with an appropriate well depth can be specified.
Boxes and Gel-Paks: A plastic box with customizable, foam inserts work well for capillary bundles and some laser machined micro-components; foam contamination of parts can occur. Gel-Pak containers find periodic use for short parts; however, some silicone residue is possible. The gel adhesion number should be specified if known; Gel-Pak 4 is common for low mass parts.
Custom Containers: Molded plastic style containers are a good option for high volume parts. In addition, nested Styrofoam packages are good for fragile items such as capillary with laser machined ends. Cooperative development of custom packaging allows for designs that are mutually beneficial.
The number of parts per package should always be considered. In some instances parts must be individually packaged, but in most cases parts can be packaged together as a group. The key consideration from a product quality standpoint is the impact of part to part interaction during packaging, transport, and handling. Glass on glass contact between parts will normally result in some level of damage to both parts. In some cases this is not a problem, while in others it can result in low performance or even part failure. For example, glass on glass contact is to be avoided if a high optical quality external surface is to be maintained. Protective coatings, such as polyimide often allow for multi-part packaging of components, even if small sections of the coating are removed. Certainly a relationship exists between the amount of coating removed and the appropriate packaging format. In almost every case, individually packaging will add cost. Coordinating the quantity per package with anticipated usage rate or production batch size is suggested and will improve ease-of-use.
Identification of parts for batch traceability is often of paramount importance. Typically labels will include material number, description, quantity, batch number, and date of manufacture. If additional items are needed, they should be included in the specification.
Thorough consideration of packaging materials, quantity, and labeling during development of product specifications is important. Polymicro Technical Specialists can assist in determining your packaging specifications.
(1) "Capillary Products" The Book on the Technologies of Polymicro, p 3–5, (2005).
Polymicro Technologies, A subsidiary of Molex Incorporated
18019 North 25th Avenue, Phoenix, AZ 85023
tel. (602) 375-4100, fax (602) 375-4110
Website: www.polymicro.com
The Benefits of Custom Bonded Silica
April 1st 2025Not all chromatography resins are created equal. Off-the-shelf chromatography resins might not always meet the rigorous purification requirements of biopharmaceutical manufacturing. Custom bonded silica from Grace can address a wide range of separation challenges, leading to real performance improvements. Discover more about the latest innovations in chromatography silica from Grace, including VYDAC® and DAVISIL®.
5 Things to Consider When Selecting a Chromatography Silica
April 1st 2025Particularly in the pharmaceutical industry, drug purity isn’t just a goal – it’s essential for achieving safety, stability and efficacy. However, purification is easier said than done, especially with challenging molecules like DNA and RNA “oligonucleotides,” due in large part to their diversity and the range of impurities that can be generated during production. Enter DAVISIL® chromatographic silica, with a wide range of pore diameters and particle sizes to meet your specific application, performance and sustainability requirements. Before you choose the chromatography resin for your next purification application, take a look at these 5 considerations.
Automating Protein Purification: Efficiency, Yield, and Reproducibility
March 27th 2025Recent advancements in automated protein purification stress the importance of efficiency, scalability, and yield consistency. This eBook compares different purification platforms, highlighting their impact on downstream applications and demonstrating how automation enhances throughput and process control.
MilliporeSigma: Ultrapure Water for Sensitive LC-MS Analysis of Pesticides
March 25th 2025The aim of the study was to illustrate the efficiency of Milli-Q® water purification systems in eliminating pesticides from tap water, thereby producing and delivering reliable and consistent-quality ultrapure water suitable for pesticides analysis