LC–MS-Compatible Analysis of Cyclic Peptides
The UHPLC analysis of four cyclic peptides is shown. Based on the hydrophobicity of the peptides, a YMC-Triart Bio C4 UHPLC column was chosen for this application.
Application Note: UHPLC–MS Analysis of Glyphosate and AMPA
The analysis of FMOC-derivatized glyphosate and AMPA in water samples was performed using a YMC-Triart C18 UHPLC column at an elevated pH of 9.5.
Equivalent GC Systems Performance for Regulatory Method Compliance and Validation
Methods migration from updating analytical equipment can be a time consuming task. This paper shows many examples of method compatibility and analytical equivalency.
LC–MS Workflow for Host Cell Proteins
LC–MS workflow for accurate quantification/detection of individual host cell proteins, from sample preparation to the reporting of values of process-related impurities.
Food Testing & Environmental Analysis Compendium
Get Greener Preparative HPLC Solutions by Eliminating Solvents
Customer Story: PFAS Monitoring
ICP-MS Analysis of Trace Elements in Open-Ocean Seawater
Case Study: TGA-FTIR-GC/MS to Advance Microplastic Research
USP-Compliant HPLC Analysis of Lamotrigine
Efficient and accurate HPLC analysis of lamotrigine in compliance with USP
HPLC Analysis of Hydrocortisone in Accordance with the United States Pharmacopeia
USP-compliant assay analysis of hydrocortisone using a PerkinElmer LC 300 HPLC System
USP-Compliant HPLC Analysis of Pregabalin
Efficient and compliant HPLC analysis of pregabalin
Analysis of Sugars in Maple Syrup by HILIC with Refractive Index Detection
Determination of four complex carbohydrates utilizing a PerkinElmer LC 300 HPLC System, a hydrophilic interaction chromatography (HILIC) technique
Microchip Capillary Electrophoresis Mass Spectrometry: A Powerful Tool for Biotherapeutic Characterization
Analysis of Saccharides in High Fructose Corn Syrup
HPLC method for saccharide content determination via method CRA SACCH.03 through the analysis of nine commercially available high fructose corn syrups
Fast LC–MS/MS Analysis
A review of considerations when optimizing high-throughput methods and achieving fast analyses on Avantor® ACE® HTP-MS columns with examples of key LC–MS separations.
HPLC Analysis of 16 Cannabinoids
Determination of 16 common cannabinoids utilizing a PerkinElmer LC 300 HPLC System
Application Note: Detection of Preservatives in Personal Care Products
A robust and sensitive HPLC method with multi-wavelength UV–vis detector for the analysis of 2-phenoxyethanol and seven parabens in commercially available PCPs
Analysis of Phytoestrogen Isoflavones in Dietary Supplements by HPLC–UV
USP-compliant method for determination of six isoflavone compounds in dietary supplement capsules with the PerkinElmer LC 300 UHPLC System with PDA detector
VOC Metabolites in Urine by HPLC with UV Detection
A rapid and simple LC method for the analysis of six common VOC metabolites in urine for monitoring occupational exposure to VOCs
Evaluation of Mixed-Mode Ion Exchange SPE for the Extraction of Opioids from Human Urine by UHPLC-MS/MS
This application notes introduces an SPE LC–MS/MS methodology using the Microlute™ CP SCX SPE 96-well microplate for the determination of 12 opioids from human urine.
App Note: An Introduction to Low-Pressure GC-MS (LPGC-MS)
LPGC–MS is a technique that uses the MS vacuum system, along with a specially designed column setup, to lower pressure inside the entire column, speeding up analysis.
Identification and Quantification of Human Milk Oligosaccharides by HPTLC
This application note describes how human milk oligosaccharides (HMO) can be analyzed by HPTLC during different production steps (fermentation and finished products).
Application Note: Hydrocarbon Fractionation Using Enviro-Clean Fusion®Ag+
This application note outlines the fractionation of hydrocarbons into aliphatic and aromatic fractions using UCT’s new silver-phase EPH fractionation cartridges.
Ph. Eur. Monograph 2244: Tacrolimus Monohydrate Related Substances on Luna® 3 µm C18(2) and Luna Omega 3 µm C18
We show the separation of tacrolimus from its related substances following Ph. Eur. monograph 2244 using the Luna 3 µm C18(2) and Luna Omega µm.
Separation of Diazoxide and its Organic Impurities per USP Monograph
We report the separation of diazoxide and its related organic impurities using a Kinetex ™2.6 µm biphenyl column according to the USP monograph for diazoxide.
The Ultimate Guide to HPLC/UHPLC Reversed-Phase Selectivity
This step-by-step selectivity guide is an overview of the reversed-phase HPLC/UHPLC options available to you, highlighting the differences between the columns.
USP Paliperidone Assay and Organic Impurities on Luna® Omega 3 µm Polar C18
LC–UV assay and organic impurities for paliperidone drug substance based on USP monograph where a L1 (C18) column with 100 x 4.6 mm, 3 µm dimensions was used
LC–MS/MS Separation of Furosemide and its Metabolite Using the Kinetex ® 2.6 µm Biphenyl, Luna® Omega 1.6 µm C18, and Luna Omega 1.6 µm Polar C18 Columns
LC–MS/MS method to separate furosemide and its metabolite using three different columns: Kinetex 2.6 µm Biphenyl, Luna Omega 1.6 µm C18, and Luna Omega 1.6 µm Polar C18
Luna Omega C18 Application eBook
Luna Omega 1.6µm, 3µm, and 5µm HPLC/UHPLC columns culminate 20 years of technological prowess, advancements, and innovation.