Ultra-high sensitivity, expanded flexibility, increased stability and robustness - the new Nexera X2 UHPLC system targets routine analysis and applications in highly regulated environments demanding complex system setups.
Ultra-high sensitivity, expanded flexibility, increased stability and robustness - the new Nexera X2 UHPLC system targets routine analysis and applications in highly regulated environments demanding complex system setups.
System flexibility
The system flexibility is based on software features which control multiple gradients in a single system. This enables automated solvent blending on each pump in a binary gradient setup. The software has been adapted to meet the requirements for use in highly regulated environments.
Stability
Stability in gradient use has been improved by pump side modifications. Furthermore, design changes on inlet valve and degassing unit minimize air bubbles passing through the flow line and reduce their negative effects on stability and performance. For addressing specific applications, additional micro reactor based mixing devices can be selected accordingly. A newly designed low volume quaternary option reduces the system volume to meet UHPLC needs while enabling a better inter-system method transfer.
Sensitivity
The new SPD-M30A photodiode array detector is perfectly suited ultra-high sensitive applications using a capillary cell with low dispersion. Total reflection and a high energy deuterium lamp guarantee a low noise level. A novel temperature control principle decreases baseline drift and offers improved reliability even under changing environment conditions. Together with ultra-high speed data acquisition, software features which maximize resolution on the PDA while enabling peak deconvolution squeeze the maximum information out of a single analysis.
For more information please visit www.shimadzu.eu
LCGC’s Year in Review: Highlights in Liquid Chromatography
December 20th 2024This collection of technical articles, interviews, and news pieces delves into the latest innovations in LC methods, including advance in high performance liquid chromatography (HPLC), ultrahigh-pressure liquid chromatography (UHPLC), liquid chromatography–mass spectrometry (LC–MS), and multidimensional LC.
Using LC-MS/MS to Measure Testosterone in Dried Blood Spots
December 19th 2024Testosterone measurements are typically performed using serum or plasma, but this presents several logistical challenges, especially for sample collection, storage, and transport. In a recently published article, Yehudah Gruenstein of the University of Miami explored key insights gained from dried blood spot assay validation for testosterone measurement.