Staphylococcus aureus (S. aureus) evades clearance by the immune system by hijacking the very traps it produces, transforming these same traps into a toxic compound according to a paper published in Science.1 Scientists from the University of Chicago (Chicago, USA) used high performance liquid chromatography coupled to mass spectrometry (HPLC?MS) to identify the toxin as 2?-deoxyadenosine (dAdo).
Staphylococcus aureus (S. aureus) evades clearance by the immune system by hijacking the very traps it produces, transforming these same traps into a toxic compound according to a paper published in Science.1 Scientists from the University of Chicago (Chicago, USA) used high performance liquid chromatography coupled to mass spectrometry (HPLC–MS) to identify the toxin as 2’-deoxyadenosine (dAdo).
Bacterial invasion of tissue triggers an array of processes as part of the immune response, in an attempt to first contain and then destroy an infection. S. aureus can permanently colonize the human body without causing harmful effects, usually on the skin and within the nose causing boils or abscesses. However, if it enters the blood stream it can result in blood poisoning, endocarditis, and meningitis among other conditions.
S. aureus tissue infections are characterized by abscesses formed by immune cells cornering off the infection for clearance by a specific type of cell known as a macrophage — so-called “big eaters” that roam the body clearing away infections. The traps are released by neutrophils (neutrophil extraceullar traps [NETs]) in an attempt to contain the infection until the arrival of the macrophage. In the case of S. aureus however, there is no macrophage activity and the infection remains uncleared.
To investigate this mystery, S. aureus was co-cultured alongside immune cells, including neutrophils and macrophages. When NET production was activated, the macrophage began to die suggesting the production of a toxin by the bacterium. The team performed HPLC–MS to identify this toxin as 2’-deoxyadenosine (dAdo). Combining these results with data from genetic experiments using mutant strains of S. aureus, the team deduced that the bacterium converted NETs to dAdo that is toxic to macrophages.
Olaf Schneewind, senior author of the paper, said: “These bacteria have endowed themselves with weapons to not only anticipate every immune defense, but turn these immune defenses against the host as well.” He added: “Sooner or later almost every human gets some form of S. aureus infection. Our work describes for the first time the mechanism that these bacteria use to exclude macrophages from infected sites.”
So what does this mean for drug development? Theoretically, scientists could target this mechanism of evasion using therapeutic proteins to block bacterial enzymes involved in the transformation of NETs by S. aureus. This is promising but requires a lot more work.
Reference
1. V. Thammavongsa et al., Science342, 863–866 (2013).
Best of the Week: Food Analysis, Chemical Migration in Plastic Bottles, STEM Researcher of the Year
December 20th 2024Top articles published this week include the launch of our “From Lab to Table” content series, a Q&A interview about using liquid chromatography–high-resolution mass spectrometry (LC–HRMS) to assess chemical hazards in plastic bottles, and a piece recognizing Brett Paull for being named Tasmanian STEM Researcher of the Year.
Using LC-MS/MS to Measure Testosterone in Dried Blood Spots
December 19th 2024Testosterone measurements are typically performed using serum or plasma, but this presents several logistical challenges, especially for sample collection, storage, and transport. In a recently published article, Yehudah Gruenstein of the University of Miami explored key insights gained from dried blood spot assay validation for testosterone measurement.
Determination of Pharmaceuticals by Capillary HPLC-MS/MS (Dec 2024)
December 19th 2024This application note demonstrates the use of a compact portable capillary liquid chromatograph, the Axcend Focus LC, coupled to an Agilent Ultivo triple quadrupole mass spectrometer for quantitative analysis of pharmaceutical drugs in model aqueous samples.