Thermo Fisher Scientific and MayLab Analytical Instruments Collaborate
April 9th 2007Thermo Fisher Scientific Inc., and MayLab Analytical Instruments, manufacturer of LC and LC-MS multi column selection and column switching system solutions, announce the release of new software control for MayLab's MistraSwitch multi column selector for the Mistral oven with the Thermo Scientific Surveyor Plus HPLC.
Buffer Preparation — Hints, Tips and Common Errors
April 1st 2007Accurate preparation and correct selection of buffers is essential to obtain reproducible and consistent results in capillary electrophoresis (CE). A number of factors should be considered in buffer optimization, including the pKa of the buffering ion and the analyte as well as the molarity of the acid or base used in the adjusting procedure. Accurate recording of the precise reagents used and the procedures performed is necessary to prepare buffers consistently. "Poor reproducibility of results and poor quantitative precision will be attainable in CE assays without significant attention being paid to the preparation of buffers used."
Recent Improvements in Benchtop GC–MS
April 1st 2007The 30-year history of advances in gas chromatography–mass spectrometry technology continues today. Recent improvements in hardware, electronics, and data analysis software have resulted in new levels of productivity and sensitivity that have broadened the potential applications for this laboratory mainstay.
Mass spectrometers are effective for identifying and quantifying unknown molecules, such as disease-related proteins and small molecules in pharmaceutical research and medical diagnosis. In addition, mass spectrometry (MS) can be particularly powerful when analyzing molecules with complex structures, such as posttranslationally modified proteins. Among various MS approaches, high-resolution multistep tandem MS (MS-MS) is an emerging methodology for accurate identification of complex molecules. In this article, we describe a new approach for mass analysis with enhanced quantitative capability combined with high-resolution multistep MS-MS, where the dynamic range of quantitation covers four orders of magnitude.
The Role of Spectral Accuracy in Mass Spectrometry
April 1st 2007The ability to perform accurate mass measurements in mass spectrometry (MS) for elemental composition determination (ECD, also known as formula identification) provides a powerful tool for assisting in the identification of unknown compounds. Recent advances in data processing methods have demonstrated the ability to obtain mass accuracy in the 5–10 ppm range on routine single- and tandem-quadrupole systems (1,2), sufficient to assist in the formula identification. However, even on more expensive high-resolution systems such as quadrupole time-of-flight (qTOF) or Fourier transform (FT)–MS instruments that are capable of routinely measuring mass accuracy in the 1–3 ppm range, the formula identification is not unique, particularly for higher molecular weight compounds. By calibrating instruments to obtain high spectral accuracy as well as mass accuracy, the ability to unambiguously identify the formula is improved substantially, particularly on low-resolution systems.
ICP-MS: When Sensitivity Does Matter
April 1st 2007It makes intuitive sense - the higher the sensitivity of an inductively coupled plasma–mass spectrometry (ICP-MS) system, the lower the detection limit. But there are many factors that affect the detection limit for a given isotope in a given sample. These factors include sensitivity, background noise, and interferences.
Technology Forum: Gas Chromatography
March 22nd 2007Each month in our Technology Forum we will feature a discussion between industry experts on various trends and issues in the chromatography field. This month's Technology Forum looks at the topic of gas chromatography and the trends and issues surrounding it. Joining us for this discussion are Mark Collins, Gas Chromatography Product Manager at Perkin Elmer, and Jaap de Zeeuw, International Specialist GC consumables at Restek.