All
HPLC 2023 Analysis of Carbohydrates in Food Using a New Anion Exchange Column SweetSep™ AEX200
August 2nd 2023The AEX200 column demonstrate (a) fast separation of mono-, di- and trisaccharides in various food sample matrices, (b)sensitive quantification of carbohydrates down to femtomole levels, (c) high-resolution separation of high-molecular weight oligosaccharides with a degree of polymerization up DP of 60.
HPLC 2023 New Anion-Exchange Columns for the Analysis of N-Glycans Using HPAEC-PAD/MS
August 2nd 2023Separation of all 6 glycan monosaccharides of interest and 2-Deoxy-D-Glucose (glycosylation inhibitor) was achieved within 7 minutes using the new SweetSep™ AEX20 column under isocratic elution conditions. Furthermore, profiling of released N-glycans from glycoproteins without the need for sample derivatization is shown using HPAEC-MS.
Increase Lab Productivity Anytime, From Anywhere
July 31st 2023The waters_connect™ System Monitoring is the latest innovation in lab management, providing real-time information for all Empower-controlled chromatography systems via the waters_connect cloud platform. Coordinating laboratory work and responding dynamically to changing priorities has never been easier.
Adaption of Retention Models to Allow Optimization of Peptide and Protein Separations
July 25th 2023This application note discusses the use of the LC Simulator module to accurately model retention and peak width of proteins and peptides in analytical scale reversed phase and ion exchange chromatography.
Merck Simplifies and Streamlines Method Development with In Silico Modeling
July 25th 2023Retention modeling has proven to be a successful technique in accelerating method development and optimization. This case study gives a more detailed insight into how scientists at Merck use computer-assisted modeling to develop robust methods faster.
The rise of tech bio: Powering life science innovation
July 20th 2023Explores the ways in which tech bio is transforming the life science industry. Hear from Dr Kath Mackay, Director of Life Sciences at Bruntwood SciTech and leaders from NorthWest EHealth, Elixir Software and Cellular Highways as they share their perspectives on how tech bio has advanced their businesses.
Quantitative Analysis of Azido Impurities in Five Sartan Drug Substances using Triple Quad LCMS
July 11th 2023The work illustrates a single LCMS method for the analysis of AZBT and AMBBT in five sartan drug substances, with full separation of all sartans and azido impurities achieved in only 8.5 minutes.
Data Integrity Compliance in the Analytical Laboratory
July 11th 2023LabSolutions DB/CS software offers powerful support for ensuring compliance with data integrity requirements for all types of analytical instruments, and can be optimized for a wide range of laboratory sizes and operating styles. Download this file to learn more.