Application Notes: LC
Application Note: LC–HRMS Analysis of the ASO Mipomersen
Mipomersen was analyzed by LC–HRMS using a biocompatible YMC-Triart C8 metal-free column, ensuring symmetric peaks, high sensitivity, and no carryover effects.
UHPLC Analysis of Cell-Penetrating Peptides
The separation of three cell-penetrating peptides (CPPs) was performed using a YMC-Triart C18 UHPLC column, providing sharp peaks for a fast analysis in under 4 min.
LC–MS/MS Analysis of PFAS in Human Serum
Twenty-eight PFAS in human serum were analyzed using a YMC-Triart C18 column. An automated SPE system was coupled to an online SPE column-switching LC–MS/MS method.
HILIC Analysis of Hydrophilic Dipeptides
Four hydrophilic dipeptides were separated with excellent resolution using a YMC-Triart SIL column. Even structurally similar dipeptides were separated in under 4 min.
LC–MS-Compatible Analysis of Cyclic Peptides
The UHPLC analysis of four cyclic peptides is shown. Based on the hydrophobicity of the peptides, a YMC-Triart Bio C4 UHPLC column was chosen for this application.
Application Note: UHPLC–MS Analysis of Glyphosate and AMPA
The analysis of FMOC-derivatized glyphosate and AMPA in water samples was performed using a YMC-Triart C18 UHPLC column at an elevated pH of 9.5.
USP-Compliant HPLC Analysis of Lamotrigine
Efficient and accurate HPLC analysis of lamotrigine in compliance with USP
HPLC Analysis of Hydrocortisone in Accordance with the United States Pharmacopeia
USP-compliant assay analysis of hydrocortisone using a PerkinElmer LC 300 HPLC System
USP-Compliant HPLC Analysis of Pregabalin
Efficient and compliant HPLC analysis of pregabalin
Analysis of Sugars in Maple Syrup by HILIC with Refractive Index Detection
Determination of four complex carbohydrates utilizing a PerkinElmer LC 300 HPLC System, a hydrophilic interaction chromatography (HILIC) technique
Analysis of Saccharides in High Fructose Corn Syrup
HPLC method for saccharide content determination via method CRA SACCH.03 through the analysis of nine commercially available high fructose corn syrups
HPLC Analysis of 16 Cannabinoids
Determination of 16 common cannabinoids utilizing a PerkinElmer LC 300 HPLC System
Analysis of Phytoestrogen Isoflavones in Dietary Supplements by HPLC–UV
USP-compliant method for determination of six isoflavone compounds in dietary supplement capsules with the PerkinElmer LC 300 UHPLC System with PDA detector
VOC Metabolites in Urine by HPLC with UV Detection
A rapid and simple LC method for the analysis of six common VOC metabolites in urine for monitoring occupational exposure to VOCs
Ph. Eur. Monograph 2244: Tacrolimus Monohydrate Related Substances on Luna® 3 µm C18(2) and Luna Omega 3 µm C18
We show the separation of tacrolimus from its related substances following Ph. Eur. monograph 2244 using the Luna 3 µm C18(2) and Luna Omega µm.
Separation of Diazoxide and its Organic Impurities per USP Monograph
We report the separation of diazoxide and its related organic impurities using a Kinetex ™2.6 µm biphenyl column according to the USP monograph for diazoxide.
Allowable Adjustments to European Pharmacopoeia (EP) Methods
Easily determine the allowable adjustments that can be made to European Pharmacopoeia (EP) methods and find the right column for your method.
USP Allowable Adjustments Guide
Quickly view allowable adjustments outlined by the United States Pharmacopeia (USP) and select the proper Phenomenex column for your monograph using this simple guide.
Pharmacopeia Application eBook for Small Molecule Analysis
Improve United States Pharmacopeia (USP) method performance with allowable adjustments
Detection of Preservatives in Personal Care Products
A robust and sensitive HPLC method with multi-wavelength UV–vis detector for the analysis of 2-phenoxyethanol and seven parabens in commercially available PCPs .
Lentivirus Aggregate Screening Using Centrifugal Field-Flow Fractionation
Critical quality attributes of lentivirus vector products can be assessed by centrifugal field-flow fractionation coupled to multi-angle light scattering (CF3-MALS).
Separation of Halo Acetic Acids by Ion Exclusion v2
Accurate detection of HAAs is paramount for the prevention of over oxidation, while still managing enough water sanitation to eliminate water-borne pathogens.
Flexible Anion Analysis with Hamilton PRP-X100 and X110 Columns v3
Chemically resistant resin bed allows for a wide base of mobile-phase choices with excellent anion separation.
Arsenic Speciation on Hamilton PRP-X100 v3
Contamination of drinking water and food sources is of great concern. Isolation and quantification of the various arsenic states are identified.
Separation of Selected Components of Ylang-Ylang Oil v2
Isolation of six common allergens by the utilization of reversed-phase HPLC using an alkaline eluent
Hexavalent Chromium Determination Hamilton PRP-X100 Anion Exchange HPLC Column v3
Chromium can pose as a beneficial element or a poison, therefore it is imperative to identify contaminated waters, especially drinking water.
Isolation of Paclitaxel v2
The fight against cancer employs many tools. Paclitaxel, a compound found in the bark of the Pacific yew tree, is one that that has been found to make a big difference.
Surveying LC Columns for Levetiracetam Analysis
A variety of C18-type columns are evaluated for the identification of levetiracetam via the USP monograph.
HPLC Analysis of Levetiracetam Organic Impurity
Symmetrical, well-resolved peaks easily meet USP performance requirements for the analysis of levetiracetam impurities.
HPLC Analysis of Pramipexole Dihydrochloride
Symmetrical, well-resolved peaks easily meet USP performance requirements for the analysis of pramipexole dihydrochloride.