Scientists in the USA have carried out an investigation into the variety of beverages enjoyed by the Northern Bronze and Iron Age peoples before written records began using a combination of analytical chemical techniques.
Scientists in the USA have carried out an investigation into the variety of beverages enjoyed by the Northern Bronze and Iron Age peoples before written records began using a combination of analytical chemical techniques.1
Led by Patrick E. McGovern from the University of Pennsylvania Museum of Archaeology and Anthropology, Pennsylvania, USA, the team analyzed the residues found on pottery and bronze vessels taken from four different sites in Denmark and Sweden. The vessels ranged in age from approximately 1500 BC to the first century AD.
The team found that the preferred beverage was a hybrid or “grog” consisting of a fermented mixture of honey, fruit (bog cranberry and lingonberry), and cereals (wheat, rye, and/or barley), and, sometimes, grape wine. The compounds were identified by Fourier-transform infrared spectrometry (FT–IR); gas chromatography–mass spectrometry (GC–MS); ultrahigh-pressure liquid chromatography (UHPLC) tandem MS; and headspace solid-phase microextraction (SPME) coupled to GC–MS.
Of particular note was the presence of grape wine, imported from further south in Europe. According to the authors of the paper, this has an important cultural significance as it demonstrates the social and ceremonial prestige attached to wine. In addition, it also indicates an active trading network across Europe as early as the Bronze Age.
Classical writers would often depict the Northern-dwelling inhabitants as savages. McGovern commented: “Far from being the barbarians so vividly described by ancient Greeks and Romans, the early Scandinavians emerge with this new evidence as a people with an innovative flair for using available natural products in the making of distinctive fermented beverages. They were also not averse to importing and drinking the southern beverage of preference, grape wine, though sometimes mixed with local ingredients.” This is the first time that the import of grape wine in this era has been chemically proven.
Reference
1. Patrick E. McGovern et al., Danish Journal of Archaeology, DOI: 10.1080/21662282.2013.867101 (2013).
Best of the Week: Food Analysis, Chemical Migration in Plastic Bottles, STEM Researcher of the Year
December 20th 2024Top articles published this week include the launch of our “From Lab to Table” content series, a Q&A interview about using liquid chromatography–high-resolution mass spectrometry (LC–HRMS) to assess chemical hazards in plastic bottles, and a piece recognizing Brett Paull for being named Tasmanian STEM Researcher of the Year.
Using LC-MS/MS to Measure Testosterone in Dried Blood Spots
December 19th 2024Testosterone measurements are typically performed using serum or plasma, but this presents several logistical challenges, especially for sample collection, storage, and transport. In a recently published article, Yehudah Gruenstein of the University of Miami explored key insights gained from dried blood spot assay validation for testosterone measurement.
Determination of Pharmaceuticals by Capillary HPLC-MS/MS (Dec 2024)
December 19th 2024This application note demonstrates the use of a compact portable capillary liquid chromatograph, the Axcend Focus LC, coupled to an Agilent Ultivo triple quadrupole mass spectrometer for quantitative analysis of pharmaceutical drugs in model aqueous samples.