All
Oligonucleotide Analysis with FlexFire WP C18 1.6 µm (Sept 2022)
This application note covers high-resolution oligonucleotide analysis using FlexFire’s new Wide Pore (WP) C18 1.6 µm column.
Fast and Rugged Direct Analysis of Polar Pesticides in Spinach
This fast, simple LC-MS/MS workflow for the direct analysis of polar pesticides in spinach provides good retention and peak shape over hundreds of matrix injections.
Efficient Peptide Desalting Using Tecan’s Proprietary NBE™ Columns
Tecan’s proprietary NBE format SPE columns enable desalting in the column before peptide extraction. Read this app note to see how Tecan can accelerate your workflows!
PFAS Testing Guide: Wastewater, Soil, and Sediments
Application guide to advanced sample preparation for chromatography analysis and mass spectrometry techniques for PFAS's more difficult matrices.
HS–GC–FID: Survey of Ethanol Content in Fermented Food and Drink
This study shows high-throughput ethanol in food method analyzing for alcohol content in a variety of commercially available beverages and foods.
GC-FID: Analysis of Residual Solvents and Monomers in Plastic
Residual monomers and solvents can present health risks or impact performance of final product. Learn about this method that can help you meet the most stringent purity requirements.
GC–FID: Sensitive Routine Analysis of Commercial Flex Fuel Gasoline (E85) by ASTM Method D5501-2
This study shows a method that provides ideal separation efficiency and quantitative repeatability for ASTM Method D5501-20 analysis.
Increased Productivity, High Accuracy, and Precision in the Determination of 18 PFAS by EPA 537.1
Laboratory productivity increase is demonstrated using an SDVB polymer SPE and C18 column selectivity.
PFAS Interlaboratory Study from Potable and Non-potable Water Samples
Multiple laboratories applied method EPA 537.1 and 533 for the extraction of PFAS in pristine non-potable water and source water assessment.
GC–FID: Limit of Diethylene Glycol and Ethylene Glycol According to USP Propylene Glycol Monograph
Learn about a GC-FID method that identifies propylene glycol and defines a limit test for ethylene glycol and diethylene glycol.
GC–FID: Limit of Cetyl Alcohol and Aliphatic Alcohol Impurities According to USP
Learn about residual impurities in cetyl alcohol method, according to the USP monograph, that offers enhanced compound resolution and highly repeatable injections.
Managing Cross-contamination in PFAS Sampling, Extraction, and Analysis
PFAS experts provide insight on workflow considerations on how to manage and prevent cross-contamination to ensure quality analysis.
UHPLC Analysis of Monoclonal Antibodies Using YMC-Triart Bio C4
YMC-Triart Bio C4 is used to successfully analyze monoclonal antibodies in reversed-phase mode in this robust application.
New Application Guide: Persistent Organic Pollutants (POPs) by GC
A comprehensive selection of applications for the determination of Persistent Organic Pollutants (POPs)
Improved Metabolomic Analysis Using an Iron-Free Flow Path
In metabolomics analysis, the use of a biocompatible LC system has significant advantages over a stainless steel LC, as demonstrated in this application.
GC–FID: Limit of Ethylene Glycol and Diethylene Glycol in Polyethylene Glycol 400 According to USP Monograph
This study focuses on PEG samples having a molecular weight of less than 450 where USP specifies a GC–FID using a packed column as the analytical method of choice.
FAQ on PFAS Unregulated Contaminants Monitoring Rule (UCMR 5)
FAQ on scope, workflow, timeline, requirements for the Fith Unregulated Contaminants Monitoring Rule (UMCR 5)
High Resolution Analysis of Monoclonal Antibodies
This application demonstrates that YMC-BioPro IEX SF is an outstanding stationary phase for the characterization of charge variants in mAbs.
UHPLC Separation of 11 Cannabinoids on YMC-Triart C18 ExRS
This application note demonstrates the use of YMC-Triart C18 ExRS for UHPLC potency analysis of 11 common cannabinoid compounds.
Extraction and Analysis of GenX, from Water by LC-MS/MS
Analysis of HFPO-DA in a multi-residue method along with 24 other common PFAS
GC-FID: Analysis of Fatty Acid Methyl Esters (FAMEs) in Edible Oils and Food Products
Fast method that provides excellent resolution and highly repeatable separations helping to improve data quality and increase laboratory productivity.
From Forensic Bench Chemist to Senior Product Manager: Bridging the Gaps Between Software and Real-World Application
Optimization of Phosphorothioate Oligonucleotide separation using BioPro IEX QF
Achieve narrow peaks and high sensitivity by optimizing the separation of phosphorothioate oligonucleotides in 5 steps using the strong anion exchanger BioPro IEX QF.
The Right HIC Column for Each Separation (Sept 2022)
This application note explores when to use each of YMC’s two HIC columns by comparing retention behaviors of BioPro HIC HT and BioPro HIC BF.
Volatile Petrochemical Hydrocarbons Analysis
Analysis of volatile petrochemical hydrocarbons in the environment by fully automated workflow (flow-modulated headspace–GC×GC–FID) for efficient sample quantitation
Profiling of Controlled Substances Using GC-TOF-MS
Using GC–TOF-MS for comprehensive profiling of seized drug samples, for confident identification of controlled substances, as well as adulterants and cutting agents
Selecting the Optimal Column for Native SEC–MS of Monoclonal Antibodies
Exosome Characterization in Biological Matrices Using Asymmetrical Flow Field-Flow Fractionation and Nanoparticle Tracking Analysis
Analyzing Microplastics in Salt Samples
Application note describing how thermal desorption–GC–MS is used to address multiple challenges in the detection of microplastics in different salt samples
Quantitative LC-UV Method for CBD in Topicals with Simplified Extraction of Lotions, Balms, and Creams