Hamilton PRP-X100 and PRP-X110 are the perfect solution for anion analysis in water or environmental samples. The robust design and covalent surface modification of the packing material lead to a highly increased lifetime as compared to the competition. The production process is compliant to ISO 9001 ensuring an outstanding column-to-column and lot-to-lot reproducibility.
Hamilton polymeric PRP-X100 and PRP-X110 anion exchange columns are the easy way to separate inorganic and organic anions from 10 ppb to 500 ppm without elaborative pre-concentration or suppression. Virtually all mobile phases, based, for example, on hydroxide, carbonate, benzoate, or phthalate eluent, can be used with PRP-X columns to provide good performance for any kind of anion separation.
Column-to-column reproducibility has become one of the most critical aspects of column quality. Nobody wants to develop a method only to find out that the column that they purchase later for the same application does not perform in the same manner. Every Hamilton column is produced according to ISO 9001, validated and delivered with a certificate of analysis to ensure perfect reproducibility of your results.
PRP-X100 and PRP-X110 columns are packed with a high quality polystyrene-divinylbenzene (PSDVB) resin of well defined porosity with covalent bounded trimethylammonium anion exchange groups. This highly inert polymeric support resists chemical attacks from organic solvents and aqueous buffers (0–100% aqueous or organic; pH 1 to 13), effectively lengthening the column lifetime. The columns may be cleaned under harsh conditions to completely remove any persistent contamination and the subsequent regeneration procedure will quickly return your chromatography back to its original state.
PRP-X100 and PRP-X110 columns can be used with any existing HPLC or ion chromatograph to easily determine a large variety of anions in almost any sample matrix including air, water, and soil, for example:
Figure 1: Example applications of PRP-X100 anion exchange columns.
Besides, high quality anion analysis may be performed without substantial investment since HPLC systems equipped with a simple UV-detector are available in most laboratories.
Figure 2: Example applications of PRP-X110 anion exchange columns-especially developed for maximum efficiency and trace level analytics. A: Separation of weak anions with conductivity detection. B: Separation of standard anions at low concentration with conductivity detection.
Hamilton PRP-X100 and PRP-X110 are the perfect solution for anion analysis in water or environmental samples. The robust design and covalent surface modification of the packing material lead to a highly increased lifetime as compared to the competition. The production process is compliant to ISO 9001 ensuring an outstanding column-to-column and lot-to-lot reproducibility.
Hamilton Company
4970 Energy Way, Reno, NV 89502
tel. (775) 858-3000, fax (775) 856-7259
Website: www.hamiltoncompany.com
Separation of Ultra-Short and Long Chain PFAS Compounds Using a Positive Charge Surface Column
December 11th 2024A separation of ultra-short and long chain PFAS (C1-C18) is performed on a HALO®PCS Phenyl-Hexyl column along with a HALO®PFAS Delay column which demonstrates excellent retention for both hydrophilic and hydrophobic analytes.