Spark Application Note
The method developed runs on a fully automated platform integrating solid-phase extraction (SPE) and LC (Symbiosis Pico) without any manual pretreatment step(s). Automatic pretreatment results in high throughput, low CVs and high precision. Sample preparation has been simplified to just one operator step before the system takes over the automated analysis of the samples.
A Spark Holland Symbiosis PICO system with a Mistral column oven and an Applied Biosystems/MDS Analytical Technologies API 4000 LC–MS–MS system are used for this application. The API 4000 is equipped with a Heated Nebulizer (APCI) probe.
Symbiosis Pico is Spark Holland's unique (u)HPLC solution with integrated on-line SPE-LC–MS automation. The system offers large flexibility in processing different types of samples selecting one of the three fully automated operational modes LC; XLC (extraction liquid chromatography) and mXLC (multidimensional on-line SPE)
Sample preparation consists of diluting a human sample with a special protein disrupting buffer, followed by mixing. Samples are then placed in the Symbiosis autosampler. 100 μL of sample is injected on a Spark HySphere C8EC-SE sorbent SPE cartridge for on-line sample clean-up and concentration.
The mobile phase consists of formic acid, water and methanol with separation on a Merck KGaA Chromolith SpeedROD RP-18e (endcapped), 50 × 4.6 mm HPLC column. An example chromatogram of the separation achieved is shown in Figure 1.
Figure 1
A calibration curve was created by injecting a full set of calibration standards ranging from 5 to 500 ng/mL spiked human plasma. The calibration curve is calculated with a R2 of 0.999 with a 1/X weighting for both compounds.
Table 1: Accuracy and precision of the QC samples.
This method was evaluated using spiked human sodium heparin plasma samples. The developed on-line SPE-MS–MS method has an absolute recovery of more then 90%, and calibration curve with a linear range from 5–500 ng/mL (R = 0.999 for both compounds). The developed method has an accuracy ranging from 89–117% and precision of 0.1–7.9 %CV. The estimated quantification limits for both analytes are more than sufficient to allow the analytical method to be used for therapeutic drug monitoring. When injecting 100 μL, containing 50 μL of plasma, a detection limit of 5 ng/mL is achieved.
1. Spark application note 0053-080-01.
2. Applied Biosystem Vitamin D i-method (User Contributed i-method by Spark).
For more information please send an e-mail to: Applications@sparkholland.com
Spark Holland bv
P. de Keyserstraat 8, PO box 3887800 AJ Emmen, The Netherlands
E-mail: Applications@sparkholland.com Website: www.sparkholland.com
A Matrix-Matched Semiquantification Method for PFAS in AFFF-Contaminated Soil
Published: April 14th 2025 | Updated: April 14th 2025Catharina Capitain and Melanie Schüßler from the Faculty of Geosciences at the University of Tübingen, Tübingen, Germany describe a novel approach using matrix-matched semiquantification to investigate per- and polyfluoroalkyl substances (PFAS) in contaminated soil.