Separation of a Mix of Acidic, Basic, and Neutral Compounds at High pH Conditions
February 1st 2014The unique surface chemistry of the Flare diamond core-shell column combines ionic and hydrophobic separation mechanisms to effectively retain a variety of chemical species in a single run.
Leveraging Mass Defect Plots for Compound Identification in Complex Matrices by GC-HRT
February 1st 2014Gas chromatography coupled to high resolution time-of-flight mass spectrometry (GC–HRT) was used to identify halogenated organic compounds based on their mass defects in fish tissue extracts.
Considerations for Switching from Helium to Hydrogen for Gas Chromatography Carrier Gas
February 1st 2014As the cost of helium increases and its availability decreases, an increasing number of Gas Chromatography (GC) professionals are considering switching to hydrogen gas for their carrier gas.
Molecular Weight Determination of Unfractionated Heparin
February 1st 2014Heparin is a polydisperse, heterogeneous polysaccharide derived from animal tissue. Heparin has been used as an anticoagulant for over 60 years and one of the fundamental parameters for characterizing unfractionated heparin (UFH) is its molecular weight (MW) and MW distribution.
Application of Paper Strip Extraction in Combination with LC–MS-MS in Pharmacokinetics
February 1st 2014Recent advances in sampling techniques in the pharmaceutical industry sparked significant interest in applying improvements to extraction methods for greater analyte detection and quantitation.
Hexavalent Chromium Determination Hamilton PRP-X100 Anion Exchange HPLC Column
February 1st 2014Chromium (Cr) is a metal with an interesting relationship to the environment. Whereas trivalent chromium (Cr(III)) is an essential nutrient, hexavalent chromium (Cr(VI)) is a poison to humans and aquatic life and poses serious environmental and ecological threats.
Optimizing LC–MS and LC–MS-MS Methods
February 1st 2014Many parameters within liquid chromatography–mass spectrometry (LC–MS) methods are "locked and left" - that is, they are optimized using a few methods when new, then only changed if absolutely necessary because of poor analytical performance.
The Automated Extraction of Aqueous Samples by Method EPA 8270D Using the TurboTrace ABN SPE System
February 1st 2014EPA 8270D calls for the extraction for analysis of semi-volatile analytes in various matrices. Target analytes mentioned in the method cover a wide range of compound classes resulting in reporting lists that often approach 100 compounds.