The Application Notebook
A new, immobilized chiral stationary phase (CSP) based on a novel chiral selector for HPLC and SFC is described. Its unique selectivity as a complement to Daicel's other commercial immobilized polysaccharide CSPs is demonstrated.
Clint Amoss and Geoff Cox, Chiral Technologies, Inc
Pilar Franco and Tong Zhang, Chiral Technologies Europe
A new, immobilized chiral stationary phase (CSP) based on a novel chiral selector for HPLC and SFC is described. Its unique selectivity as a complement to Daicel's other commercial immobilized polysaccharide CSPs is demonstrated.
The development of immobilization technologies in combination with the popular polysaccharide-based chiral stationary phases has led to the possibility to use new selectors which have hitherto been inaccessible. One such chiral selector is cellulose tris(3,5-dichlorophenylcarbamate). This was identified as being too soluble to make successful chiral stationary phases by Okamoto some years ago (1). More recently, using photochemical and thermal immobilization techniques, Francotte has demonstrated the wide selectivity range and capability of this selector (2). A new commercial material, CHIRALPAK® IC™, is now available, based upon cellulose tris(3,5-dichlorophenylcarbamate) polymer immobilized on silica using proprietary techniques.
Figure 1
Columns 4.6 × 250 mm (Daicel Chemical Industries, Ltd) were used throughout. Flow rates of 1 mL/min (Tropic acid and Prilocaine) or 1.5 mL/min (Devrinol) were used. Agilent and Shimadzu HPLC systems fitted with autosamplers and diode array detectors set at appropriate wavelengths for the compounds concerned were employed.
Figure 2
The figures show three examples of separations which, while difficult to achieve using pre-existing immobilized stationary phases (CHIRALPAK IA™ and IB™), are easy to perform with the new selectivity of CHIRALPAK IC. It is interesting to note that two of the separations were performed with MTBE-based mobile phases with CHIRALPAK IC. These solvent mixtures may only be used with immobilized polysaccharide-based CSPs.
Figure 3
CHIRALPAK IC demonstrates the expected unique selectivity from its chiral selector. In many cases its selectivity is complementary to the other immobilized polysaccharide-based CSPs, leading to a high degree of success in screening for chiral method development using a combination of all three columns.
(1) Y. Okamoto, M. Kawashima, and K. Hatada, J. Chromatogr. 363, 173 (1986).
(2) E. Francotte and D. Huynh, J. Pharm. Biomed. Anal. 27, 421 (2002).
Chiral Technologies, Inc.
800 North Five Points Rd, West Chester, PA 19380
tel. 1-800-6-CHIRAL
Pick Your Poison. Isolation of Paclitaxel (Mar 2025)
March 7th 2025The diterpenoid, paclitaxel, which was identified as a potent chemotherapy agent for breast and ovarian cancer originates from the Pacific Yew tree. The isolation of paclitaxel from its major impurities is shown with the use of Hamilton’s PRP-1 (5 µm) HPLC column.