Researchers at the University of Castilla-La Mancha (Spain), Ecole Nationale des Sciences Appliquees (Agadir, Morocco), and Institut Agronomique et Veterinaire Hassan II (Agadir, Morocco) developed a method for screening paraquat and diquat in olive oil samples.
Researchers at the University of Castilla-La Mancha (Spain), Ecole Nationale des Sciences Appliquees (Agadir, Morocco), and Institut Agronomique et Veterinaire Hassan II (Agadir, Morocco) developed a method for screening paraquat and diquat in olive oil samples. The method involves supercritical fluid extraction (SFE) before continuous flow electrochemical detection. Samples that exhibit total concentrations close to or above a 0.05-g/g threshold limit are then analyzed by liquid chromatography with diode-array detection.
Analytical Challenges in Measuring Migration from Food Contact Materials
November 2nd 2015Food contact materials contain low molecular weight additives and processing aids which can migrate into foods leading to trace levels of contamination. Food safety is ensured through regulations, comprising compositional controls and migration limits, which present a significant analytical challenge to the food industry to ensure compliance and demonstrate due diligence. Of the various analytical approaches, LC-MS/MS has proved to be an essential tool in monitoring migration of target compounds into foods, and more sophisticated approaches such as LC-high resolution MS (Orbitrap) are being increasingly used for untargeted analysis to monitor non-intentionally added substances. This podcast will provide an overview to this area, illustrated with various applications showing current approaches being employed.
Study Explores Thin-Film Extraction of Biogenic Amines via HPLC-MS/MS
March 27th 2025Scientists from Tabriz University and the University of Tabriz explored cellulose acetate-UiO-66-COOH as an affordable coating sorbent for thin film extraction of biogenic amines from cheese and alcohol-free beverages using HPLC-MS/MS.
Multi-Step Preparative LC–MS Workflow for Peptide Purification
March 21st 2025This article introduces a multi-step preparative purification workflow for synthetic peptides using liquid chromatography–mass spectrometry (LC–MS). The process involves optimizing separation conditions, scaling-up, fractionating, and confirming purity and recovery, using a single LC–MS system. High purity and recovery rates for synthetic peptides such as parathormone (PTH) are achieved. The method allows efficient purification and accurate confirmation of peptide synthesis and is suitable for handling complex preparative purification tasks.