Application Notes: Food and Beverage
Extraction and analysis of PFAS from soil
This application note demonstrates how accelerated solvent extraction (ASE) can extract a variety of PFAS from soil.
HPAE-PAD of Galactosyl-Oligosaccharide-Containing Samples
This application note demonstrates dual eluent generation cartridge performance for profiling galactosyl-oligosaccharides using HPAE-PAD.
Sorbitol determination in food
Thermo Scientific Dionex CarboPac PA300-4µm column allows simplified, high-resolution sorbitol separation and quantification in complex samples.
Agave syrup carbohydrate analysis using HPAE-PAD
This application note demonstrates how Norma Oficial Mexicana for agave syrup carbohydrate analysis is executed with a Thermo Scientific Dionex CarboPac PA1-1 mm column using HPAE-PAD in EGC mode.
Analysis of Pesticides in Spinach
The efficacy of the JMS-TQ4000GC triple-quadrupole GC–MS/MS for measuring pesticides in spinach purchased from local grocers is described in this application note.
Analysis of Pesticides in Honey
The efficacy of the JMS-TQ4000GC triple-quadrupole GC-MS/MS for measuring pesticides in honey purchased from local apiaries is described in this application note.
Analysis of Pesticides in Kale
The efficacy of the JMS-TQ4000GC triple-quadrupole GC-MS/MS for measuring pesticides in kale purchased from local grocers is described in this application note.
Starch Amylose and Amylopectin Molar Mass and Size Distributions by FFF-MALS
Application Note from Hamilton - Separation of Aflatoxins on HxSil C18
Summary of FDA Method C-010.01: Determination of 16 Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS) in Food Using Liquid Chromatography–Tandem Mass Spectrometry (LC–MS/MS)
Tomato Pesticide Determination with GCxGC-TOFMS
Pesticide residues in food can cause a number of adverse health effects. By using GCxGC-TOFMS, you can determine exactly what residues are in your food.
Garlic, Panacea or Placebo
Sulfide compounds found in garlic oils are used in therapeutics and prophylaxis of certain cancers and are prevalent in cell health.
Legumes – Blessing and Curse?
Identification and quantification of the raffinose family of oligosaccharides allows a more thorough understanding of an individual’s gut health.
Saccharide Identification in Packaged Foods
Identification of the five most common saccharides found in packaged foods, lactose, maltose, sucrose, fructose, and glucose, is easily resolved on the RCX-30 column.
Summary of FDA Method C-010.01: Perfluoroalkyl and Polyfluoroalkyl Substances in Food
This application note summarizes a validated procedure developed by the US Food and Drug Administration (FDA) for the measurement of 16 PFASs in food using a QuEChERS sample preparation approach.
Monitoring Acrylamide in Real-Time During Food Production Using SIFT-MS
Known carcinogen, acrylamide is formed during food production processes such as roasting. This study details the use of SIFT–MS to monitor for this VOC in real time.
Baseline Separation of Chlorophenols
The baseline separation of various chlorophenols, that only differ in the amount and/or position of the chlorine substituents, is made possible using YMC-Triart C18 ExRS.
For Which Dioxin and POPs Applications Can the DFS Magnetic Sector GC-HRMS be Used?
Dioxins and other persistent organic pollutants are everywhere. Labs analyze samples to quantify and guarantee their results are compliant with regulations and controls.
Ensuring System Suitability for cis-trans FAMEs Analysis by AOAC 2012.13 on an Agilent 8890 GC with Retention Time Locking
The AOAC method 2012.13 determines fatty acid content in milk products and infant formula by capillary GC with flame ionization detection using the Agilent 8890 GC.
Black Pepper Authenticity Workflow Using the High-Resolution Agilent 7250 GC/Q-TOF
A novel food-authenticity workflow targeted for routine analysis distinguishes black pepper samples from different geographic regions and detects adulteration.
Quantitation of Pesticides in Strawberries at Tolerance Levels Established by the US EPAAgilent 6470 Triple Quadrupole LC/MS
How to test the suitability for the determination of pesticides in strawberries using an Agilent 8890 GC, coupled to an Agilent 7000D and 7010B GC–MS TQ.
Carbohydrates in Food Products
The ALEXYS Carbohydrates Analyzer is a robust and reliable solution for the analysis of carbohydrates in apple juice, buttermilk, malt beer, and artificial sweeteners.
What Are the Advantages of Using Magnetic Sector GC–HRMS technology for Dioxin and POPs Analysis?
Being the recognized method in worldwide regulations, Magnetic Sector offers advantages when it comes to routine quantitative analysis of Dioxins and other POPs.
Simultaneous Determination of Residual Agricultural Chemicals in Food by GC–MS/MS
Report of verified results for pesticide residues sensitivity in food using the JMS-TQ4000GC
Analysis of Pesticides in a Hemp Matrix
Pesticides in a hemp matrix were analyzed using the SRM capabilities of the JEOL JMS-TQ4000GC gas chromatograph triple-quadrupole mass spectrometer.
Stability in Quantitative Analysis of Residual Agricultural Chemicals in Food by GC–MS/MS
Report of the stability of eight pesticides that were added to a spinach extract, with good reproducibility
Analysis of Pesticides in a Cannabis Sativa Matrix
Pesticides in Cannabis sativa matrix were analyzed using the SRM capabilities of the JEOL JMS-TQ4000GC gas chromatograph triple-quadrupole mass spectrometer.
Quantitative Analysis of Pesticides in Carrot extract Using GC–MS/MS
Quantitative analysis of residual agricultural chemicals in carrot extract was undertaken using a JEOL JMS-TQ4000GC.
Quantitative Analysis of Pesticides in Spinach Extract Using GC–MS/MS
Quantitative analysis of residual agricultural chemicals in spinach extract was undertaken using a JEOL JMS-TQ4000GC.
How to Avoid Contamination in Pipetting
Preventing aerosol contamination during pipetting helps you achieve reliable results. Here we address the main contamination mechanisms that need to be avoided.