Improving Intact lgG Separations with Aeris WIEDPORE Core-Shell HPLC–UHPLC Columns

Article

The Application Notebook

The Application NotebookThe Application Notebook-02-01-2012
Volume 0
Issue 0

A new widepore core-shell HPLC–UHPLC column (aeris WIDEPORE) has been introduced that is specifically designed to improve protein separations.

A new widepore core-shell HPLC–UHPLC column (Aeris WIDEPORE) has been introduced that is specifically designed to improve protein separations. Rather than utilize a similar morphology of small molecule core-shell columns with larger pores, a completely different particle was developed that takes into account the slower diffusion of proteins into porous particles. When one looks at different intact protein separations, the resolution of different glycoforms of therapeutic IgG antibodies probably stands out as one of the more difficult due to the large size and structure of IgG. In this article improved separation of IgG is shown using Aeris core-shell HPLC–UHPLC columns.

Materials and Methods

All chemical, standards, and antibodies were obtained from Sigma Chemical (St. Louis, Missouri). Solvents were purchased from EMD (San Diego, California). Fully porous 5 µ 300 Å C18 columns and core-shell Aeris 3.6 µm WIDEPORE XB-C18 columns (100 × 4.6 mm) were obtained from Phenomenex (Torrance, California). Mouse Immunoglobulin IgG samples were analyzed on an Agilent 1200 HPLC system with autosampler, column oven, solvent degasser, and UV detector set at 214 nm. Data was collected using Chemstation software (Agilent, Santa Clara, California). Mobile phases used were 0.1% TFA in water (A) and 0.1% TFA in acetonitrile and a gradient from 10 to 40% B in 15 min was used at 1 mL/min. Column was maintained at 80 °C.

Results and Discussion

Aeris was designed to maximize resolution of proteins greater than 10 kilodaltons molecular weight regardless of HPLC (or UHPLC) system used. A thin porous shell minimizes protein peak band spreading due to diffusion in and out of the porous layer and a larger particle size reduces column backpressure allowing for the use of longer columns for increased resolution. The result is a column with performance on par or better than sub 2 µm widepore fully porous media at backpressures significantly lower than 3 µm fully porous columns. The performance advantage of Aeris WIDEPORE core-shell columns is demonstrated in Figure 1 where an Aeris column is compared to a 5 µm fully porous widepore column. IgG immunoglobulins are considered difficult proteins to separate by reversed phase LC due to their large size (150 KDa) and hydrophobicity. Typically, elevated column temperatures and isopropanol mobile phase are required to improve recovery and resolution. In this example mouse immunoglobulin IgG is compared on each column using an acetonitrile-only mobile phase at 80 °C (Aeris is stable to 90 °C). Note the significantly narrower peak width for the Aeris WIDEPORE core-shell column resulting in the resolution of the three main glycoforms of IgG versus the fully porous columns where only two components are seen. Of additional note is the greater recovery for the Aeris column; low hydrophobicity and good inertness result in greater recovery for hydrophobic proteins. The good resolution and recovery for this application demonstrate the utility of using core-shell Aeris WIDEPORE columns for immunoglobulin and large protein separations.

Figure 1: Comparison between a fully-porous 5 µm 300 Å C18 column (top chromatogram) to an aeris 3.6 µm WIDEPORE XB-C18 column (bottom chromatogram) for a mouse Ig-G sample. Note the improved resolution and greater protein recovery for the aeris wide-pore core-shell column.

Phenomenex Inc.

411 Madrid Avenue, Torrance, CA 90501

tel. (310) 212-0555; (310) 328-7768

Website: www.phenomenex.com