Application Notes: General
High Sensitivity LC–MS Screening of Cytostatics
The recently introduced 1 mm YMC-Triart C18 UHPLC column was used for the high sensitivity LC–MS screening of six antineoplastic drugs.
NP/RP Analysis of Phosphoramidites
A YMC-Triart C18 and a YMC-Triart SIL column were used in RP and NP mode, respectively, for the analysis of four different phosphoramidites.
Application Note: LC–HRMS Analysis of the ASO Mipomersen
Mipomersen was analyzed by LC–HRMS using a biocompatible YMC-Triart C8 metal-free column, ensuring symmetric peaks, high sensitivity, and no carryover effects.
UHPLC Analysis of Cell-Penetrating Peptides
The separation of three cell-penetrating peptides (CPPs) was performed using a YMC-Triart C18 UHPLC column, providing sharp peaks for a fast analysis in under 4 min.
LC–MS/MS Analysis of PFAS in Human Serum
Twenty-eight PFAS in human serum were analyzed using a YMC-Triart C18 column. An automated SPE system was coupled to an online SPE column-switching LC–MS/MS method.
HILIC Analysis of Hydrophilic Dipeptides
Four hydrophilic dipeptides were separated with excellent resolution using a YMC-Triart SIL column. Even structurally similar dipeptides were separated in under 4 min.
LC–MS-Compatible Analysis of Cyclic Peptides
The UHPLC analysis of four cyclic peptides is shown. Based on the hydrophobicity of the peptides, a YMC-Triart Bio C4 UHPLC column was chosen for this application.
Application Note: UHPLC–MS Analysis of Glyphosate and AMPA
The analysis of FMOC-derivatized glyphosate and AMPA in water samples was performed using a YMC-Triart C18 UHPLC column at an elevated pH of 9.5.
Equivalent GC Systems Performance for Regulatory Method Compliance and Validation
Methods migration from updating analytical equipment can be a time consuming task. This paper shows many examples of method compatibility and analytical equivalency.
LC–MS Workflow for Host Cell Proteins
LC–MS workflow for accurate quantification/detection of individual host cell proteins, from sample preparation to the reporting of values of process-related impurities.
Food Testing & Environmental Analysis Compendium
USP-Compliant HPLC Analysis of Lamotrigine
Efficient and accurate HPLC analysis of lamotrigine in compliance with USP
HPLC Analysis of Hydrocortisone in Accordance with the United States Pharmacopeia
USP-compliant assay analysis of hydrocortisone using a PerkinElmer LC 300 HPLC System
USP-Compliant HPLC Analysis of Pregabalin
Efficient and compliant HPLC analysis of pregabalin
Analysis of Sugars in Maple Syrup by HILIC with Refractive Index Detection
Determination of four complex carbohydrates utilizing a PerkinElmer LC 300 HPLC System, a hydrophilic interaction chromatography (HILIC) technique
Analysis of Saccharides in High Fructose Corn Syrup
HPLC method for saccharide content determination via method CRA SACCH.03 through the analysis of nine commercially available high fructose corn syrups
Fast LC–MS/MS Analysis
A review of considerations when optimizing high-throughput methods and achieving fast analyses on Avantor® ACE® HTP-MS columns with examples of key LC–MS separations.
HPLC Analysis of 16 Cannabinoids
Determination of 16 common cannabinoids utilizing a PerkinElmer LC 300 HPLC System
Application Note: Detection of Preservatives in Personal Care Products
A robust and sensitive HPLC method with multi-wavelength UV–vis detector for the analysis of 2-phenoxyethanol and seven parabens in commercially available PCPs
Analysis of Phytoestrogen Isoflavones in Dietary Supplements by HPLC–UV
USP-compliant method for determination of six isoflavone compounds in dietary supplement capsules with the PerkinElmer LC 300 UHPLC System with PDA detector
VOC Metabolites in Urine by HPLC with UV Detection
A rapid and simple LC method for the analysis of six common VOC metabolites in urine for monitoring occupational exposure to VOCs
Evaluation of Mixed-Mode Ion Exchange SPE for the Extraction of Opioids from Human Urine by UHPLC-MS/MS
This application notes introduces an SPE LC–MS/MS methodology using the Microlute™ CP SCX SPE 96-well microplate for the determination of 12 opioids from human urine.
App Note: An Introduction to Low-Pressure GC-MS (LPGC-MS)
LPGC–MS is a technique that uses the MS vacuum system, along with a specially designed column setup, to lower pressure inside the entire column, speeding up analysis.
Identification and Quantification of Human Milk Oligosaccharides by HPTLC
This application note describes how human milk oligosaccharides (HMO) can be analyzed by HPTLC during different production steps (fermentation and finished products).
Application Note: Hydrocarbon Fractionation Using Enviro-Clean Fusion®Ag+
This application note outlines the fractionation of hydrocarbons into aliphatic and aromatic fractions using UCT’s new silver-phase EPH fractionation cartridges.
Application Note : Analysis of e-liquids According to ISO 20714
In this application note we demonstrate the excellent performance of Sapiens-624MS columns for the analysis of e-liquids based on ISO 20714.
Detection of Preservatives in Personal Care Products
A robust and sensitive HPLC method with multi-wavelength UV–vis detector for the analysis of 2-phenoxyethanol and seven parabens in commercially available PCPs .
Evaluation of Empore StageTips for Peptide Desalting
This application note demonstrates rapid peptide desalting prior to LC-MS analysis in Proteomics research using different micropipette SPE StageTips packed with CDS Analytical’s Empore SPE membranes.
Lentivirus Aggregate Screening Using Centrifugal Field-Flow Fractionation
Critical quality attributes of lentivirus vector products can be assessed by centrifugal field-flow fractionation coupled to multi-angle light scattering (CF3-MALS).
Extractions of THC-metabolites from Urine
This application note demonstrates a sample preparation procedure for using the Empore C18 SPE cartridge for the extraction of the THC metabolite, THC-COOH, from urine samples.