Application Notes: Biopharmaceuticals
Introducing PSG® Biotech
PSG® Biotech offers a comprehensive portfolio of pumps, sensors and flow meters engineered to protect media integrity and product quality while producing the highest yields
Ultra-Robust High-Throughput Peptide Quantification (V3)
This application note shows a micro-flow LC–MS method developed on the Thermo Scientific Vanquish Neo UHPLC system is suitable for high-throughput proteomic analyses of large sample cohorts.
Ultra-Robust High-Throughput Peptide Quantification (V2)
New Standards for Bottom-up Proteomics (V3)
This application note reveals the Thermo Scientific Vanquish Neo UHPLC system offers maximal MS utilization for direct injection workflows and versatility to separate peptides at low flow rates.
New Standards for Bottom-up Proteomics (V2)
Optimizing Control of Pump-Related Biopharma-Production Processes
This application note will illustrate how a new integrated pump controller is giving users automated control of pump operations in critical biopharma applications.
New Standards for Bottom-up Proteomics
This application note reveals the Vanquish Neo offers maximal MS utilization for direct injection workflows and versatility to separate peptides at low flow rates.
Ultra-Robust High-Throughput Peptide Quantification
This application note shows a micro-flow LC–MS method developed on the Vanquish Neo UHPLC is suitable for high-throughput proteomic analyses of large sample cohorts.
Oligonucleotide Mapping Using BioPharma Finder Software
The development of comprehensive liquid chromatography–high resolution accurate mass workflows for confident identification and mapping of oligonucleotides.
AN: Optimizing Control of Pump-Related Processes
This white paper will illustrate how integrated pump controllers optimize pump performance by automatically controlling flow or pressure.
Application Note: Electrochemical Reduction of Biopharmaceuticals
With a new electrochemical cell, complete reduction of inter- and intra-disulfide bonds in mAbs is achieved. For cystine knots peptides, the sequence coverage was 100%.
Complementary Analysis with a 2D-LC–MS Instrument for Flexible Operation
This goal of this note is identity confirmation of protein-based impurities of a therapeutic protein by multi heart-cut 2D-LC–MS in a top-down experiment.
App Note: Optimizing Control of Pump-Related Processes
Application Note: Optimizing Control of Pump-Related Processes
Optimizing Control of Pump-Related Processes
Electrochemical Reduction of Biopharmaceuticals
With a new electrochemical cell, complete reduction of inter- and intra-disulfide bonds in mAbs is achieved with superior sequence coverage.
HILIC Analysis for Polar Modifications of Proteins and Peptides
Learn the advantages of HILIC to measure and monitor glycosylation, deamidation, and oxidation, which are critical for the function and form of proteins and peptides.
Adding MALS to Preparative IEC
Multi-angle light scattering couples inline with ion exchange chromatography to estimate the aggregate content of protein fractions without additional offline assays.
Targeted Small Protein Analysis with a Single Quadrupole Mass Detector
This tech note demonstrates the benefits of single quadrupole mass detection for small protein analysis.
Application Note: AAV Application Notebook
AAV characterization and stability screening are achieved with multi-angle light scattering coupled to separation methods and high-throughput dynamic light scattering.
High-Resolution Analysis of Monoclonal Antibodies Using the Cation Exchange Column BioPro IEX SF
This application note investigates the use of YMC BioPro SF for high-resolution charge variant analysis of four therapeutic mAb products.
Method Development of IEX mAb Separations Using YMC BioPro IEX Columns and Dial-a-Mix v2
The dial-a-mix method with a quaternary pump HPLC quickly screens different method conditions when developing ion-exchange methods for charge variant analysis of mAbs.
Use of YMC-Triart PEEK-Lined Columns for Improved Peak Shape of Coordination Compounds
This application note describes the benefits of using YMC-Triart PEEK-lined columns for separations involving coordination compounds.
HPLC Separation of 11 Cannabinoids on YMC-Triart C18
This application note investigates using YMC-Triart C18 for analysis of 11 common cannabinoid compounds.
Next Generation RP Phase for Enhanced Insulin Purification
This application note details real-life client data obtained for insulin purification and manufacturing using YMC’s new YMC-Triart Prep Bio200 C8 material.
YMC SEC Columns and Light Scattering Detection
This application note details the use of light scattering detection coupled with SEC analysis for characterization of proteins and antibodies.
AAV Application Notebook
Learn how AAVs are characterized for critical quality attributes and stability by multi-angle and dynamic light scattering.
µPAC Generation 2: nanoLC Column Performance
The unique design of the 50 cm μPAC™ GEN2 nanoLC column provides superior performance over state-of-the-art packed bed columns, achieving peak capacities of over 1000.
Analyzing multiple AAV CQAs with SEC-MALS
This note describes how SEC-MALS-UV-RI analysis quantifies multiple critical quality attributes of AAV viral vectors, including concentration/titer, aggregation and empty:full ratio.
Rapid Analysis of Plasmid Topoisomers
AEX using a TSKgel® DNA-NPR column offers a rapid method for discriminating between covalently closed circular, open circular, and linear forms of plasmid DNA.