Copper Oxide Particles for Protein Analysis via MALDI-MS

News
Event

A recent study conducted protein analysis using matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) and a platform that utilizes copper oxide particles.

Article Highlights

  • Introduction of a novel platform utilizing synthesized copper oxide particles for MALDI-MS addresses a longstanding limitation in intact protein identification methods.
  • The Cu2O PS@DHB hybrid platform demonstrates high effectiveness in analyzing intact proteins with molecular weights up to 150,000 Da, including complex proteins like immunoglobulin G (IgG) and bovine serum albumin (BSA), as well as glycopeptides.
  • Researchers attribute the success of the platform to the unique surface properties of the synthesized copper oxide particles, which enhance biomolecule interaction and ionization efficiency.

A recent study from KTH Royal Institute of Technology in Stockholm, Sweden, explored using a platform that utilizes synthesized cooper oxide particles to conduct matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) for protein analysis.

The study addresses a notable gap in existing research, where the application of simple platforms in MALDI-MS for intact protein identification has been limited (1). However, the team's Cu2O PS@DHB hybrid platform, requiring only 2.5 mg/mL of particles and 10 mg/mL of DHB, proved to be highly effective without the need for surface modification of target plates (1).

The researchers showed in their study that the platform was effective at analyzing intact proteins with molecular weights up to 150,000 Da, including prominent proteins like immunoglobulin G (IgG), bovine serum albumin (BSA), and cytochrome C (1). Furthermore, the platform showcased its versatility by successfully analyzing glycopeptides from IgG digests, extending its application to the low m/z range (2500–3000 Da) (1).

copper glow particle bokeh background, abstract glitter wallpaper illustration. Generated with AI. | Image Credit: © ArtistiKa - stock.adobe.com

copper glow particle bokeh background, abstract glitter wallpaper illustration. Generated with AI. | Image Credit: © ArtistiKa - stock.adobe.com

The researchers investigated why their Cu2O PS@DHB platform was successful. Attributing the success to the synthesized copper oxide particles, the researchers believe that the particles’ surface and optical properties improved upon the interaction with biomolecules, which improved ionization efficiency (1). The homogeneous distribution achieved on the spot surface ensures high reproducibility for MS analysis across an extended mass range (1).

The researchers hoped that their methodology would also be simple for researchers to reproduce. As the study showed, the simplified process detected intact proteins with complex structures and large sizes effectively (1). The methodology also was able to detect glycopeptides at low concentrations (1). The findings suggest promising implications for clinical and diagnostic research, where the combination of Cu2O PS@DHB with appropriate enrichment procedures could prove invaluable (1).

This study accomplishes two objectives: it expands the scope of MALDI-MS applications, and it also highlights the potential of environmentally friendly synthesis routes for developing advanced analytical tools in bioanalysis and diagnostics (1). As a result, this study advances protein analysis, and has implications in medical and biological research.

This article was written with the help of artificial intelligence and has been edited to ensure accuracy and clarity. You can read more about our policy for using AI here.

Reference

(1) Springer, V.; Zhou, Y.; Aguilera, A. Y.; Emmer, A. User-friendly Platform for Analysis of High Mass Intact Proteins and Glycopeptides by Laser Desorption/Ionization–Mass Spectrometry based on Copper Oxide Particles. Anal. Bioanal. Chem. 2024, 416, 861–872. DOI: 10.1007/s00216-023-05072-0