Webinar Date/Time: Thu, Jun 8, 2023 11:00 AM EDT
Very volatile organics (VVOCs) such as ethylene oxide in foods and the gas components in water can be analyzed in accordance with regulations thanks to the boost in sensitivity augmenting the capabilities of traditional headspace or solid-phase microextraction (SPME) when run on less sensitive detectors.
Register Free: https://www.chromatographyonline.com/lcgc_w/new-life
Event Overview:
Modern analytical laboratories still suffer from lengthy and laborious manual preparation steps and low sensitivity. This is the case especially with ageing gas chromatography-mass spectrometry (GC-MS) systems and the need to detect ever-decreasing levels imposed by regulatory bodies. Ingress of water or unwanted volatile interferences from the extraction process always pose an additional challenge, oftentimes resulting in poor-quality data.
Robotic automation is commonly used to reduce preparation steps and increase productivity, and its effectiveness can be improved further with the addition of a sample concentration system. This significantly enhances the sensitivity of VOC/SVOC analysis by HS- and SPME-trap and/or thermal desorption (TD).
This webinar will review how very volatile organics (VVOCs) such as ethylene oxide (amongst other residual fumigants) in foods as well as the gas components (Freons R-12, R-22 and vinyl chloride) in water can be analyzed in accordance with regulations and beyond. This is thanks to the boost in sensitivity augmenting the capabilities of traditional headspace or solid-phase microextraction (SPME) when run on less sensitive detectors. Thus, lower detection limits can be reached while maintaining focused, sharp peaks and good signal-to-noise for confident detection.
Examples will be shown of the adoption of the Centri platform in routine analysis and in those research workflows where full sample characterization is needed to make better decisions. Another inherent benefit of Centri is its compatibility with hydrogen carrier gas, future-proofing ageing GC-MS and safeguarding against rising helium shortages. Centri extraction and concentration platforms easily integrate with existing assets so that maximizing ROI is possible with minimal capital investment.
Key Learning Objectives:
Who Should Attend:
Speaker:
Rachael Szafnauer
Product Marketing Manager, Extraction & Enrichment
Markes International
Rachael Szafnauer received an MSci in Forensic Science from the University of South Wales, UK. Her final-year project focused on fingerprinting emerging psychoactive substances using advanced techniques such as GCxGC–TOF MS in collaboration with Markes International. She later took up the role of thermal desorption product specialist at Markes, providing technical and application support to the commercial team. She then took on her current role as product marketing manager for the Centri product line and specializes in the development of applications using extraction and enrichment techniques for GC-MS.
Register Free: https://www.chromatographyonline.com/lcgc_w/new-life
Study Explores Thin-Film Extraction of Biogenic Amines via HPLC-MS/MS
March 27th 2025Scientists from Tabriz University and the University of Tabriz explored cellulose acetate-UiO-66-COOH as an affordable coating sorbent for thin film extraction of biogenic amines from cheese and alcohol-free beverages using HPLC-MS/MS.
Quantifying Microplastics in Meconium Samples Using Pyrolysis–GC-MS
March 26th 2025Using pyrolysis-gas chromatography and mass spectrometry, scientists from Fudan University and the Putuo District Center for Disease Control and Prevention detected and quantified microplastics in newborn stool samples.
The Role of SPME Combined with GC–MS for PFAS Analysis
Published: March 25th 2025 | Updated: March 25th 2025Emanuela Gionfriddo and Madison Williams from University at Buffalo, the State University of New York, NY, USA discuss the important role that solid-phase microextraction (SPME) techniques with gas chromatography mass spectrometry (GC–MS) can play in the analysis of per- and polyfluoroalkyl substances (PFAS).
Multi-Step Preparative LC–MS Workflow for Peptide Purification
March 21st 2025This article introduces a multi-step preparative purification workflow for synthetic peptides using liquid chromatography–mass spectrometry (LC–MS). The process involves optimizing separation conditions, scaling-up, fractionating, and confirming purity and recovery, using a single LC–MS system. High purity and recovery rates for synthetic peptides such as parathormone (PTH) are achieved. The method allows efficient purification and accurate confirmation of peptide synthesis and is suitable for handling complex preparative purification tasks.