Application Notes: General
Analyses of Polymer Branching
eBook: Optimizing the Analysis of Viral Vectors with Light Scattering
Hyaluronic Acid MW and Conformation by SEC-MALS-IV
Garlic, Panacea or Placebo
Sulfide compounds found in garlic oils are used in therapeutics and prophylaxis of certain cancers and are prevalent in cell health.
Simple Method Transfer with Integrated HPLC
Application of a Dual Injection (U)HPLC for the Analysis of Pharmaceuticals
How to Maximize Your High-Performance Liquid Chromatography Method Development
Improving Peak Shape Using an Automatic Pretreatment Function (Co-Injection)
Perchlorate Quantitation in Drinking Water Using Suppressed Anion Chromatography Coupled with Single Quadrupole MS
Analysis of PFAS Compounds in Fish Tissue Using Offline Supercritical Fluid Extraction and LC-MS/MS
Maximizing Analytical Efficiency with Real-time Mobile Phase Monitoring
Analysis of 16 EPA PAHs by GC/MS Using Hydrogen Carrier Gas
Hydrogen is great choice of carrier gas for GC when analyzing of low-level PAHs by GC/MS. On-demand gas generation offers an analytically superior, cost-effective and safe solution over helium.
Use One LC for Two USP Pregabalin Analyses
This application note demonstrates automation of the assay and determination of enantiomeric purity according to USP on one LC system. No manual interaction is required.
Let Your Autosampler Do Your Pipetting-V2
This technical overview describes the automated preparation of calibration solutions offered by the injector program available with Agilent autosamplers.
Determine Nitrosamines in Active Pharmaceutical Ingredients
This application note describes the highly sensitive analysis of nitrosamine impurities in active pharmaceutical ingredients to quantify genotoxic impurities.
Run Multimethod Pesticide Analysis
This application note shows the LC/MS analysis of multiresidue pesticides. For the pesticide compounds, quantification, linearity, and matrix recovery limits are shown.
Simplify Your Method Development
This application note demonstrates how a method development workflow, including MS, can be greatly simplified using the latest instrumentation and automation features.
Quantify Total Fluorine Content with ProfilerF
The ProfilerF analyzer is a unique analytical tool that quantifies all fluorine, defining the total impact of PFAS contamination in industrial wastewater.
Automate Sample Derivatization for Amino Acid Analysis
This application note shows the LC–FLD analysis of amino acids with in-loop derivatization, for fast reaction times, reproducible yield and separation, and low LODs.
Challenges and solutions to improve the quality in beverage quality control processes
Quantification of Polymer Contamination in Solvents
Quantitative analysis of polymer contamination in solvents by pyrolyzing the sample into a GC–MS.
Legumes – Blessing and Curse?
Identification and quantification of the raffinose family of oligosaccharides allows a more thorough understanding of an individual’s gut health.
Extraction of Amphetamines from biologicals using Clean Screen DAU
This application note describes a simple and robust solid-phase extraction (SPE) procedure for amphetamines in blood, plasma/serum, urine, and tissue samples.
Material Characterization of 3D Printing Polymers Using Pyrolysis-GC/MS
6495C Best Practices Guide
Better Smarter GC
Better, smarter GC for pollutant testing
Separation of 12 Nucleosides on Hamilton PRP-1 Column
Modified nucleosides, either natural or synthetic, often provide RNA with distinctive properties useful in diagnostics or therapeutics.
The Rapid Separation of Basic Drug Compounds under Alkaline pH Conditions on pH-Stable, Hamilton PRP-C18
The PRP–C18 isolates structurally diverse pharmaceutical compounds in under 6 minutes using basic solutions.
Oligonucleotide Separation Using Reversed-Phase Ion Pairing Chromatography
Ion pairing agent aided separation of oligonucleotides from their potential failure sequences highlighting the Hamilton family of reversed-phase HPLC columns.