Shimadzu and Frontier Lab provide a new versatile tool for the comprehensive analysis of polymer samples. It consists of Shimadzu’s GCMS-QP2010 quadrupole series and Frontier Lab’s new Multi-Shot EGA/PY-3030D vertical micro furnace pyrolyzer. Both companies have teamed up in Pyrolysis-GCMS for years.
The PY-3030D is equipped with a low thermal mass ceramic heater featuring improved thermal stability and an extended temperature range from ambient + 10 °C to 1050 °C. This enables the analysis of temperature-sensitive compounds as well as the cracking of highly temperature-stable polymers using high-temperature pyrolysis. The low mass ceramic heater and the new design of the pyrolysis/GC interface contribute to increased heating and cooling rates, leading to higher productivity because of very short heater cycle times.
Optimized temperature control ensures increased reproducibility of pyrolysis data, particularly at higher temperatures. In addition, the outstanding performance of the GCMS-QP2010 series contributes to the excellent reproducibility of the data.
The wide range of new accessories opens up new potentials for the analysis of polymers – a configuration is available for nearly every analytical challenge. The sample introduction systems offer increased application possibilities including the analysis of weathering products and reactions at high pressure. By simply changing the sampler, different sample introduction methods such as single-shot/double-shot pyrolysis, liquid injection, reactive pyrolysis or sample irradiation with UV light can be selected.
For further details please visit www.shimadzu.eu
Determining Enhanced Sensitivity to Odors due to Anxiety-Associated Chemosignals with GC
May 8th 2025Based on their hypothesis that smelling anxiety chemosignals can, like visual anxiety induction, lead to an increase in odor sensitivity, a joint study between the University of Erlangen-Nuremberg (Erlangen, Germany) and the Fraunhofer Institute for Process Engineering and Packaging (Freising, Germany) combined behavioral experiments, odor profile analysis by a trained panel, and instrumental analysis of odorants (gas chromatography-olfactometry) and volatiles (gas chromatography-mass spectrometry).
Investigating 3D-Printable Stationary Phases in Liquid Chromatography
May 7th 20253D printing technology has potential in chromatography, but a major challenge is developing materials with both high porosity and robust mechanical properties. Recently, scientists compared the separation performances of eight different 3D printable stationary phases.
Detecting Hyper-Fast Chromatographic Peaks Using Ion Mobility Spectrometry
May 6th 2025Ion mobility spectrometers can detect trace compounds quickly, though they can face various issues with detecting certain peaks. University of Hannover scientists created a new system for resolving hyper-fast gas chromatography (GC) peaks.