
LC–MS Probes Cord Blood After Preterm Labor Scares
Key Takeaways
- Suspected preterm labor frequently leads to hospitalization and intersects with developmental windows implicated in later cardiometabolic and neurodevelopmental risk, particularly when delivery occurs preterm.
- Untargeted, lipid-inclusive cord blood metabolomics identified a distinct separation between uncomplicated term neonates and neonates delivered preterm after sPTL, suggesting systematic metabolic remodeling.
Liquid chromatography–mass spectrometry (LC–MS) finds cord blood fat profiles differ after suspected preterm labor.
Sometimes pregnant women show signs of going into labor too early, but not all of them actually give birth prematurely; some go on to deliver at full term. A research team wanted to see whether babies born after these early warning signs differ chemically at birth from babies whose mothers had uncomplicated pregnancies. They also compared babies who ended up being born early with those who were born on time despite the scare. To do this, the researchers analyzed blood from the babies’ umbilical cords, taking a broad survey of the many small molecules it contained, including fats. They used liquid chromatography––mass spectrometry (LC–MS) to separate a sample into its individual chemical components and identify them and then applied several statistical methods to look for patterns. Their findings were published in the International Journal of Gynecology & Obstetrics.¹
Why Does a Preterm Labor Scare Matter?
Early signs of labor (also known as suspected preterm labor [sPTL]) are a common pregnancy complication, affecting nearly one in ten pregnancies, and they’re one of the main reasons pregnant women end up in the hospital. These warning signs come at a critical time in a baby’s development, and if the baby is born early, it can have both immediate and lasting effects on their health.2-5
People who were born prematurely face higher risks of heart problems, developmental and brain-related issues, and metabolic conditions such as obesity and trouble regulating blood sugar.6,7 Several things that can happen around an early birth, including damage from harmful molecules, serious infections, and poor blood flow through the placenta, can directly harm vital organs such as the heart, the kidneys, and the tiny blood vessels in the brain.8 In line with this, studies have found that premature and full-term newborns differ in their body chemistry, and some of those differences can last into young adulthood.9,10
Notably, about half of the women who show early signs of labor still go on to deliver at full term, after 37 weeks of pregnancy.1
Does a Preterm Labor Scare Leave a Chemical Mark on the Baby?
The researchers detected 507 different compounds in the cord blood, and all but one were common enough across the samples to include in their analysis. When they looked at the overall chemical patterns, babies born early after warning signs of labor stood apart from babies of uncomplicated pregnancies. Babies whose mothers had early warning signs but still delivered on time fell somewhere in between.1
In all, 122 compounds differed among the three groups, even after the researchers used a statistical check to rule out chance findings. The compounds that best set the groups apart were mostly fats, including types that help build cell membranes, forms of cholesterol, and hormones the body makes from cholesterol. When the researchers sorted the babies by the 25 most telling compounds, they fell into three clusters, and most babies born on time after an early scare landed in the middle one.1
There was one important limitation. Most mothers who showed early signs of labor were given steroid injections, a standard treatment to help the baby’s lungs mature in case of an early birth. Because so few of these mothers didn’t receive the steroids, the researchers could not tell whether the chemical differences came from the early labor scare itself or from the steroid treatment.1
“Cord blood metabolomic profiles differed between infants from pregnancies complicated by sPTL and infants from uncomplicated term pregnancies,” concluded the authors of the paper.1 “The persistence of an intermediate metabolic profile among infants born at term after sPTL raises the possibility of a metabolic signature associated with the preceding episode of sPTL. However, the observational design and frequent antenatal corticosteroid exposure preclude the attribution of these differences specifically to sPTL. Larger studies with adequate representation of corticosteroid-exposed and non-exposed pregnancies are warranted.”
Read More on Similar Topics
References
- Youssef, L.; Abadía-Cuchí, N.; Lerma-Irureta, J. et al. Lipid-inclusive Metabolomics of Infants Born After Suspected Preterm Labor According to Whether Delivery Occurred Preterm or At Term: A Prospective Cohort Study. Int J Gynaecol Obstet. 2026.DOI:
10.1002/ijgo.71474 - Mcpheeters, M. L.; Miller, W. C.; Hartmann, K. E. et al. The Epidemiology of Threatened Preterm Labor: A Prospective Cohort Study. Am J Obstet Gynecol. 2005, 192,1325-1330. DOI:
10.1016/j.ajog.2004.12.055 - Walani, S. R. Global Burden of Preterm Birth. Int J Gynecol Obstet. 2020; 150(1): 31-33. DOI:
10.1002/ijgo.13195 - Bacak SJ, Callaghan WM, Dietz PM, Crouse C. Pregnancy-associated hospitalizations in the United States, 1999-2000. Am J Obstet Gynecol. 2005, 192, 592-597. DOI:
10.1016/j.ajog.2004.10.638 - Ojeda, L. I.; Valencia, C. M.; Cardozo Buitrago, N, et al. FIGO Good Practice Recommendations on Preconception Care: A Strategy to Prevent Preterm Birth. Int J Gynecol Obstet. 2025, 171(2), 574-587. DOI:
10.1002/ijgo.70495 - Hofman PL, Regan F, Jackson WE, et al. Premature birth and later insulin resistance. N Engl J Med. 2004; 351(21): 2179-2186. DOI:
10.1056/NEJMoa042275 - Ou-Yang, M. C.; Sun, Y.; Liebowitz M, et al. Accelerated Weight Gain, Prematurity, and the Risk of Childhood Obesity: A Meta-analysis and Systematic Review. PLoS One2020, 15(5), 1-18. DOI:
10.1371/journal.pone.0232238 - Nuyt, A. M.; Lavoie, J. C.; Mohamed, I. et al. Adult Consequences of Extremely Preterm Birth: Cardiovascular and Metabolic Diseases Risk Factors, Mechanisms, and Prevention Avenues. Clin Perinatol. 2017, 44(2), 315-332. DOI:
10.1016/j.clp.2017.01.010 - Atzori, L.; Antonucci, R.; Barberini, L. et al. H NMR-based Metabolomic Analysis of Urine from Preterm and Term Neonates. Front Biosci. 2011, E3: 1005-1012. DOI:
10.1109/leoswt.2008.4444364 - Perrone, S.; Negro, S.; Laschi, E. et al. Metabolomic Profile of Young Adults Born Preterm. Metabolites 2021, 11(10), 697. DOI:
10.3390/metabo11100697
Related to this article








