Webinar Date/Time: Thu, Nov 7, 2024 9:00 AM PST (12:00 PM EST)
Learn how to navigate the regulatory landscape utilizing current method development technologies for impurity control in late-phase API manufacturing.
Register Free: https://www.chromatographyonline.com/lcgc_w/control-strategies
Event Overview:
This webinar will cover the method development strategies for control of nitrosamines in drug substances and drug products. There will be a focus on platform method development across liquid chromatography-tandem mass spectrometry (LC-MS-MS), high-resolution LC-MS, and gas chromatography-mass spectrometry (GC-MS), and application of these methods to challenging drug substances and drug products. The webinar will include a review of method development and validation case studies for nitrosamines of concerns, as well as strategies for drug-derived nitrosamines to ensure you bring your drugs into compliance ahead of the August 2025 deadline.
Key Learning Objectives
Who Should Attend
Speaker:
Shankar Sankaran
Director, Analytical
SK pharmteco
Shankar Sankaran is director of analytical at SK pharmteco, where he oversees method development, validation, release testing, stability studies, and reference standard management for both CDMO operations and contract analytical services. With over 16 years at the organization, Shankar previously worked as a laboratory chemist, and has taken on increasing responsibilities in quality control and method development to support API programs from early to late phases and into commercial stages.
Register Free: https://www.chromatographyonline.com/lcgc_w/control-strategies
Advances in Non-Targeted Analysis for PFAS in Environmental Matrices
March 27th 2025David Megson from Manchester Metropolitan University in Manchester, UK, spoke to LCGC International about the latest developments in non-targeted analysis (NTA) of per- and polyfluoroalkyl substances (PFAS) in environmental matrices based on a recent systematic review paper he has collaboratively published (1).
Study Explores Thin-Film Extraction of Biogenic Amines via HPLC-MS/MS
March 27th 2025Scientists from Tabriz University and the University of Tabriz explored cellulose acetate-UiO-66-COOH as an affordable coating sorbent for thin film extraction of biogenic amines from cheese and alcohol-free beverages using HPLC-MS/MS.
Quantifying Microplastics in Meconium Samples Using Pyrolysis–GC-MS
March 26th 2025Using pyrolysis-gas chromatography and mass spectrometry, scientists from Fudan University and the Putuo District Center for Disease Control and Prevention detected and quantified microplastics in newborn stool samples.
The Role of SPME Combined with GC–MS for PFAS Analysis
Published: March 25th 2025 | Updated: March 25th 2025Emanuela Gionfriddo and Madison Williams from University at Buffalo, the State University of New York, NY, USA discuss the important role that solid-phase microextraction (SPME) techniques with gas chromatography mass spectrometry (GC–MS) can play in the analysis of per- and polyfluoroalkyl substances (PFAS).