Application Notes: LC
Method Development of C18 Columns and High pH
Selectivity of two high-pH stable Agilent InfinityLab Poroshell 120 C18 columns is compared with pesticides using a pH 10 formate buffer and acetonitrile gradient.
Tandem Digestion of Monoclonal Antibodies Using Novel Cysteine Proteases
This application combines cysteine proteases IgdE and IdeS, to observe conserved and hypervariable regions of the antibody, as well as identification of other variants.
Analysis of IgdE Digested Monoclonal Antibody Fragments
IgdE allows for better characterization of the antibody and yields an intact Fc and an intact Fab fragment that can be further isolated and characterized.
Comparison of UHPLC Particles for Intact Mass Subunit Analysis of Monoclonal Antibodies
Comparing core-shell superficially porous to fully porous particles to determine efficiency required for detection, separation of low-level impurities for subunit analysis.
A Simple Quantitative Method for Monoclonal Antibody Coformulations
A reversed-phase method using a superficially porous, wide pore particle morphology for the quantitation of coformulated mAbs leads to high efficiency separations.
Improving Selectivity for Intact Mass Spectrometry of Biotherapeutic mAbs
For LC–MS analysis of NIST mAb, multiple C4 LC columns are compared to determine which provides necessary separation of impurity and avoids spectral overlap in the MS detector.
Improved Peak Shapes for Basic Analytes
The performance of basic pharmaceuticals is compared to the charged surface Agilent InfinityLab Poroshell 120 CS-C18 and a C18 with formic acid mobile phase.
Method Optimization of Purity Analysis of an Fc-Fusion Protein by Reversed-Phase HPLC
For Fc Fusion proteins a reversed-phase LC analytical method is used for either extended characterization and identification for impurities or as a simple purity method.
Superior Sample Capacity for Basic Compounds
Loading capacity and peak shape of basic pharmaceuticals were compared on the Agilent InfinityLab Poroshell 120 CS-C18 and a traditional C18 column with formic acid.
Purity Analysis for Intact Monoclonal Antibodies and Fragments
Intact reversed-phase LC method is implemented for a simple yet high-resolution analytical technique that can be used for the purity analysis of monoclonal antibodies.
From Data Integrity Regulations to Pharma 4.0
This white paper provides a vendor’s perspective on recent trends in regulations and the potential future direction for the industry referred to as “Pharma 4.0”.
Chromatography Optimization for Intact Mass Analysis of Monoclonal Antibodies
Analyzing diverse method parameters, such as temperature, gradient program, and flow rates for optimization of intact mass applications when using bioZen WidePore C4.
Using pH as a Method Development Tool
The value of a wide range of pH compatibility is explored. A pesticide mixture shows how eluent pH affects analyte retention for acids, bases, and neutrals.
Method Development of C18 Columns at Low pH
The unique selectivity of four Agilent InfinityLab Poroshell 120 C18 columns is shown with veterinary drugs using a simple formic acid and acetonitrile gradient.
Backup vs. Archive: Why You Need Both
Using Empower CDS and NuGenesis LMS to develop an archive strategy that reduces backup and recovery times and removes manual intervention is demonstrated.
Durable Data for Non-IT
Companies can seek outside help for backup and restore, disaster recovery, and system administration, but responsibility for regulated data remains with the company.
VITAQUEST Streamlines Lab Operations with NuGenesis LMS
VITAQUEST, a contract manufacturer of dietary supplements, used NuGenesis LMS to automate its workflows, improve lab efficiency, and reduce the risk for data errors.
Empower Cloud Streamlines Pharmaceutical Operations
This study shows how coupling Waters’ Empower CDS with cloud technology allowed a pharmaceutical company to streamline its global operations and connect each of its labs.
Role of Empower CDS in Electronic Record Regulation Compliance
This white paper explains the 21 CFR Part 11 and EU EudraLex Annex 11 compliance readiness of Waters Empower Software for the regulated scientific laboratory.
Managing Empower Data with NuGenesis LMS
This case study demonstrates the advantages of pairing Empower CDS with NuGenesis LMS to improve the availability of your CDS data and maximize its effectiveness.
CRO Increases Advantage by Implementing Empower CDS
A&M Stabtest, an independent CRO in the pharmaceutical industry, reduced time-consuming and error-prone manual steps in the chromatographic testing process.
CDMO Advances Data Integrity and Lab Productivity
An investment in Waters NuGenesis LMS helped a global pharmaceutical CDMO meet demands for data integrity regulatory compliance and laboratory management needs.
Method Lifecycle Management Drives Development at CDMO
This study demonstrates Waters ACQUITY UPLC with PDA/QDa technology and Empower Software were integral to successful method lifecycle management at Hovione, a global CDMO.
Importance of Business Continuity in Today’s Lab
Companies can reduce the fallout of a disaster via a business continuity plan with appropriate hardware and software, including Waters Empower BC LAC/E with SecureSync.
Halo Acetic Acid Identification by Ion–Exclusion
Accurate detection of HAA’s is paramount for the prevention of over oxidation, while still managing enough water sanitation to eliminate water borne pathogens.
High Throughput DAR Determination of Brentuximab Vedotin
YMC’s latest HIC column is used to analyse the DAR of Brentuximab Vedotin allowing higher flow rates and shorter run times thanks to the pressure resistant particle.
The Right HIC Column For Each Separation
YMC’s HIC columns, BioPro HIC HT, and BioPro HIC BF address separation requirements of different compounds. The separation behaviour of two mAbs is demonstrated.
Native Online HIC–MS Analysis of mAbs
This application note shows how a mixture of seven in-house mAbs, as well as the molecular variants of two mAbs, were characterised via HIC-MS using YMC’s BioPro HIC BF column.
Native online HIC–MS of cys-linked ADCs
In this application note the DAR of the SigmaMAb ADC-mimic was determined using YMC’s BioPro HIC BF column and a nanospray ionisation mass spectrometer.
HIC Analysis of Oxidised Monoclonal Antibodies
Monoclonal antibodies and their oxidised species are separated using YMC’s more hydrophobic BioPro HIC BF column, dedicated for low hydrophobicity proteins and oxidised mAb variants.