Webinar Date/Time: Thu, Jun 8, 2023 11:00 AM EDT
Very volatile organics (VVOCs) such as ethylene oxide in foods and the gas components in water can be analyzed in accordance with regulations thanks to the boost in sensitivity augmenting the capabilities of traditional headspace or solid-phase microextraction (SPME) when run on less sensitive detectors.
Register Free: https://www.chromatographyonline.com/lcgc_w/new-life
Event Overview:
Modern analytical laboratories still suffer from lengthy and laborious manual preparation steps and low sensitivity. This is the case especially with ageing gas chromatography-mass spectrometry (GC-MS) systems and the need to detect ever-decreasing levels imposed by regulatory bodies. Ingress of water or unwanted volatile interferences from the extraction process always pose an additional challenge, oftentimes resulting in poor-quality data.
Robotic automation is commonly used to reduce preparation steps and increase productivity, and its effectiveness can be improved further with the addition of a sample concentration system. This significantly enhances the sensitivity of VOC/SVOC analysis by HS- and SPME-trap and/or thermal desorption (TD).
This webinar will review how very volatile organics (VVOCs) such as ethylene oxide (amongst other residual fumigants) in foods as well as the gas components (Freons R-12, R-22 and vinyl chloride) in water can be analyzed in accordance with regulations and beyond. This is thanks to the boost in sensitivity augmenting the capabilities of traditional headspace or solid-phase microextraction (SPME) when run on less sensitive detectors. Thus, lower detection limits can be reached while maintaining focused, sharp peaks and good signal-to-noise for confident detection.
Examples will be shown of the adoption of the Centri platform in routine analysis and in those research workflows where full sample characterization is needed to make better decisions. Another inherent benefit of Centri is its compatibility with hydrogen carrier gas, future-proofing ageing GC-MS and safeguarding against rising helium shortages. Centri extraction and concentration platforms easily integrate with existing assets so that maximizing ROI is possible with minimal capital investment.
Key Learning Objectives:
Who Should Attend:
Speaker:
Rachael Szafnauer
Product Marketing Manager, Extraction & Enrichment
Markes International
Rachael Szafnauer received an MSci in Forensic Science from the University of South Wales, UK. Her final-year project focused on fingerprinting emerging psychoactive substances using advanced techniques such as GCxGC–TOF MS in collaboration with Markes International. She later took up the role of thermal desorption product specialist at Markes, providing technical and application support to the commercial team. She then took on her current role as product marketing manager for the Centri product line and specializes in the development of applications using extraction and enrichment techniques for GC-MS.
Register Free: https://www.chromatographyonline.com/lcgc_w/new-life
Dispersive Liquid-Liquid Microextraction: A Review and Roundup of Green Sample Prep Advancements
May 15th 2024The still relatively new technique has distinct advantages, but a few of those benefits make it incompatible with some of the currently accepted principles of green sample preparation.
TD-GC–MS and IDMS Sample Prep for CRM to Quantify Decabromodiphenyl Ether in Polystyrene Matrix
April 26th 2024At issue in this study was the certified value of decabromodiphenyl ether (BDE 209) in a polystyrene matrix CRM relative to its regulated value in the EU Restriction of Hazardous Substances Directive.